www.larius.com
18
L400
REV.
02 - 02/2020 - Cod. 150085
• Unscrew the gaskets group
(R17)
with the provided wrench
(R18)
and replace the OR gasket
(R19).
• Remove the O-ring
(R20)
and the gasket
(R21)
inside the ga-
skets group.
• Position the product gaskets group
(R22)
inside the gun, making
sure to lubricate the threads with grease.
• Place the needle
(R23)
inside the gun, making sure to lubricate
the surface with grease.
During assembling, pay attention to the direction
of the gasket (R21) which should be placed with
the sealing lip facing inward (see picture below).
R21
R20
R18
R19
R17
R22
R23
R21
R20