LARIUS GHIBLI MIX 2K
ADVANCED CONTROLS
Flow meter alarm delay:
Refers to the flow switch
which controls the passage of the washing liquid
during the washing cycle phase.
Delay time in seconds, after which the machine
signals a flow switch alarm.
The operator must press the gun to allow the
washing liquid to come out.
Then reset the alarm on the relative page.
Pump A/B speed alarm delay:
Delay time after
which the machine goes into alarm conditions,
blocking operation, after having detected a pump
speed that is lower or higher than the previously
stored speed.
The alarm is activated when the mixing machine
is configured with an external counting system
(linear encoder).
Pressure A/B speed alarm delay:
Delay time after
which the machine goes into alarm conditions, after
having found a pressure lower than that set in the
pressure sensor instrument (ApLUG 3)
The second screen shows the parameters used
to store the pumping flow speed during normal
equipment operation during the mixing phase. This
function is used to identify malfunctions on the
pump in the event that it sucks or partially sucks
the relative liquid (paint or catalyser).
In these conditions, pump speed normally increas-
es with respect to normal operation.
This page is used only if the mixing machine is
equipped with an external counting system (linear
encoders).