www.larius.com
9
I
I1
I3
I2
(opzional)
GHIBLI 30:1 for sanItatIon
REV
. 01 - 04/2020 - Cod. 150112
CAUSE SERIOUS INJURIES.
• IN CASE OF INJURIES CAUSED BY THE GUN CASTING,
SEEK IMMEDIATE MEDICAL ADVICE SPECIFYING THE
TYPE OF THE PRODUCT INJECTED.
NEVER
UNDERVALUE
A WOUND CAUSED BY THE INJECTION OF A FLUID.
• ALWAYS DISCONNECT THE SUPPLY AND RELEASE THE
PRESSURE IN THE CIRCUIT BEFORE PERFORMING ANY
CHECK OR PART REPLACEMENT OF THE EQUIPMENT.
• NEVER MODIFY ANY PART IN THE EQUIPMENT. CHECK
REGULARLY THE COMPONENTS OF THE SYSTEM.
REPLACE THE PARTS DAMAGED OR WORN.
• TIGHTEN AND CHECK ALL THE FITTINGS FOR
CONNEC-
TION BETWEEN PUMP, FLEXIBLE HOSE AND SPRAY GUN
BEFORE USING THE EQUIPMENT.
• ALWAYS USE THE FLEXIBLE HOSE SUPPLIED WITH KIT.
• THE USE OF ANY ACCESSORIES OR TOOLING OTHER
THAN THOSE RECOMMENDED IN THIS MANUAL, MAY
CAUSE DAMAGE OR INJURE THE OPERATOR.
• THE FLUID CONTAINED IN THE FLEXIBLE HOSE CAN BE
VERY DANGEROUS. HANDLE THE FLEXIBLE HOSE CARE-
FULLY. DO NOT PULL THE FLEXIBLE HOSE TO MOVE THE
EQUIPMENT. NEVER USE A DAMAGED OR A REPAIRED
FLEXIBLE HOSE.
• NEVER SPRAY OVER FLAMMABLE PRODUCTS OR
SOLVENTS IN CLOSED PLACES.
• NEVER USE THE TOOLING IN PRESENCE OF POTENTIALLY
EXPLOSIVE GAS.
The high speed of travel of the product in the hose
can create static electricity through discharges
and sparks. It is suggested to earth the equipment.
The pump is earthed through the earth cable of
the supply.
The gun is earthed through the high pressure
flexible hose.
All the conductors near the work area must be
earthed.
Always check that the product is compatible with
the materials composing the equipment
(pump,
spray gun, flexible hose and accessories)
with which
it can come into contact. Never use products
containing Halogen Hydrocarbons
(as the Methylene
Chloride,
in percentage greater than 1%)
. If these products
come into contact with aluminium parts can
provoke dangerous chemical reactions with risk
of corrosion and explosion.
Avoid approaching too much to the pump piston
rod when the pump is working or under pressure.
A sudden movement of the piston rod can cause
wounds or finger squashing.
If the product to be used is toxic, avoid inhalation
and contact by using protection gloves, goggles
and proper face shields.
Take proper safety measures for the protection
of hearing in case of work near the plant.
CONNECTION OF SUCTION AND RECIRCULATING PIPES
• Connect the suction and recirculating pipes to the pump.
The optional suction pipe(I2) (not supplied; see accessories)
can be tightened with the use of your hands, while to tighten
the recirculation pipe (I3), use a wrench. In both cases, do
not use thread sealants on the fittings.
SETTING-UP
CONNECTION TO THE FEED AIR
• For pump feed use a hose (
I1
) with an internal diameter no
lower than 10 mm.