GHIBLI 30:1 for sanItatIon
REV
. 01 - 04/2020 - Cod. 150112
CONNECTION OF SUCTION AND RECIRCULATING PIPES
•
Connect the high pressure flexible hose
(
I4
)
(not supplied;
see accessories)
to the pump and to the spray gun, paying
attention to tighten the fittings strongly
(
the use of two spanners
is suggested
).
Do not use sealant agents for fitting threads.
• Make sure the spray gun is without the atomization nozzle.
WASHING OF THE BRAND-NEW EQUIPMENT
• The equipment has been tested at our plant with light mineral
oil left inside of the pumping element as protection. Therefore,
before sucking the product, carry out a washing using a diluent.
• Dip the suction hose
(I3)
(not supplied; see accessories) into
the tank of the washing.
• Insert the recirculating pipe
(I2)
into a container (
a metal container
is suggested
).
• Open the recirculating cock
(
I5
).
•
Set the pump feed pressure at about 3 bar and open the air
passage valve.
• The pump will start working and will drain oil from the recir
-
culating pipe. Close the recirculating cock (
I5
) as soon as the
clean liquid has come out.