www.larius.com
31
STAR 3001S GUN
ED. 15 - 02/2020 - Cod. 150099
L1
L2
L1
L3
L4
L5
L5
• Unscrew and remove the adjusting ring nut (
L1
).
• Remove the low pressure air cap (
L1
).
• Check that the contacts are intact and clean. Should the metal
ring (
L2
) be excessively oxidized, provide for a light grinding
by means of fine-grain sandpaper. After this operation, wipe
any residual dust with a soft cloth.
• Check and clean the air outlet holes (
L3
) and the internal
O-ring (
L4
).
• Verify the wear and the correct position of the two rheophores
(
L5
) on the front side. Replace them, if necessary.
L.h - REMOVE THE ADJUSTING RING NUT
This procedure shall be carried out for guns with:
LOW PRESSURE
CONE TIP
L.i - REMOVE THE LOW PRESSURE AIR CAP
This procedure shall be carried out for guns with:
LOW PRESSURE
CONE TIP
CLEANER
Liquid Cleaner
Clean
CLEANER
Liquid Cleaner
Clean