www.larius.com
22
THOR
ED.
17 - 09/2020 - Cod. 150096
Fig. 15J
Fig. 16J
Fig. 17J
K
J2
OFF
J4
J5
Closed
J3
CHECK ON THE PACKING NUT
The gaskets do not need adjusting. The ring nut is only used to
fit and remove gaskets and for topping up the oil.
ROUTINE MAINTENANCE
• Remove the suction hose and the rubber hose (
J9
) and take
away the bucket of water (
J8
).
•
Now point the spray gun
(
J4
) into the container (
J5
)
and press
the trigger to recover any cleaning liquid left
.
• Run the pump’s washing cycle until clean water flows out of
the circulation hose (
J12
).
• Close the circulation tap (
J3
).
•
As the pump idles, press the
“
OFF”
(0)
switch (J2) su OFF
(0)
to stop the tooling.
• In case of long storage, we recommend you to suck and
to leave light mineral oil inside the pumping group and the
flexible hose
.
If the equipment is to be stopped for a lengthy
period of time, carry out the cleaning operations
described previously, according to the type of
product used.
In case of short stoppages, suck in some water
and leave the pump unit in the bucket (H8) for
a few minutes.
Follow the washing procedure before using again
the equipment.
Always disconnect the electrical supply and
discharge the pressure in the pump unit
(open
the discharge valve)
before carrying out any
maintenance.
Wait 30 seconds before proceeding with
maintenance operations to allow any residual
electricity to be discharged.