background image

Page 5.

Thermostat LCD

Full display

ROOM

TIME

AM

MO 

ROOM

SET

TIME

AM
PM

SU MO TU WE TH FR SA

PROG  MANUAL  AUTO

LCD Display features

1.   Temperature of Room in ( C or  F)
2.   Transmitting indicator
3.   Battery low indicator
4.   Fan operating and speed
5.   Fire indicator(low, medium or high)
6.   Selected Temperature in  C or  F)
7.   Time of day (in AM or PM)
8.   Day of week
9.   Programming mode
10. Manual mode
11. Automatic mode

°

°

°

°

Initial Display on set up

The display when the thermostat is
initially turned on or when batteries are
replaced shows;

Current room temperature;
default clock display;
Default day of the week display.

1

4

5

6

7

8

9

10

11

3

Page 14.

Settings

Change between °C and °F

Teaching RF thermostat ID code to control unit.

      

Restore factory default settings.

The automatic mode factory default settings can be restored to those
found on page 10.

With the thermostat off, press the following sequence of buttons:

‘P ’, ‘T ’, ‘T ’,‘DOWN ’

.

The thermostat temperature display can be set to°C or °F. The default is °C.

With the thermostat off, press the following sequence of buttons: 

‘P ’, ‘T ’, ‘T ’

 

,‘A/M ’

.

Please note, thermostat settings need to be actioned within a period
of 2 seconds total.

2

1. Leave the remote thermostat in the off or stand by position.
   (the room temperature and time only will be displayed)
2.The heater must be turned off at its switch located on the rhs
   of the heater.
3.Turn off the power point and fully remove power cord plug.
   (if there is no access to the power cord plug then try switching off
   the power switch which the installer has fitted externally)
4.Wait at least 30 seconds and then plug the cord plug back into
   the power point and switch on the power point,(or switch on the power switch)
   do not operate any heater buttons.
5.You have now 15 seconds to perform the code learning procedure.
6.With the remote thermostat unit still off, aim the control at the heater and
   press the button(s) in sequence within 2 seconds
             The seqence of pressing buttons is 

“P, T, T, UP ”

7.When successful, the display will show  

“LC”  

(learning code) very briefly.

Summary of Contents for Cannon

Page 1: ... the owner Part No F3754 Revision B 2010 Cannon For service to this appliance or spare parts contact the CANNON distributor email service sampfordixl com au Date installed Compliance Certificate No Sampford IXL spare parts 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS PRODUCT ...

Page 2: ...ently asked questions 15 Quick reference table 16 Back Up Switch 17 Service 18 Battery type 2 X AA batteries Battery life approximately 12 months Transmission frequency 433 92 Mhz Dimensions 140MM x 80mm x 20mm Page 1 NOTES CONTENTS INITIAL START UP 1 Disconnect heater from power supply 2 Fitted batteries to remote thermostat unit 3 connect Heater back to power supply and point Remote Thermostat a...

Page 3: ... them together then release Select Auto or Manual by pressing A M button then release The heater will only operate if the actual room temperature is lower than the required temperature Manual Mode Press A M Button to select Manual mode The required temperature can be selected by using UP or DOWN buttons Room temperature is shown at top of screen Selected temperature shown at mid screen Automatic M...

Page 4: ... of the heater is described in more detail in the following section This heater features a safety interlock mode to prevent accidental or inappropriate activation of the hand held remote control unit It requires both PWR and OK buttons be pressed at the same time to turn on the controller Page 16 Function Action Page Switch on off Change between manual and automatic mode Increase decrease temperat...

Page 5: ...uto or Manual The heater on start will operate on Low Fire and fan for approx 3 minutes The heater will then go to your preset desired settings on remote thermostat As the preset temperature is reached the heater will go to Low Fire and Low Fan If the preset temperature is exceeded the burner is extinguished and the fan will run on at low setting for approximately 3 min If room temperature is stil...

Page 6: ...N The thermostat temperature display can be set to C or F The default is C With the thermostat off press the following sequence of buttons P T T A M Please note thermostat settings need to be actioned within a period of 2 seconds total 2 1 Leave the remote thermostat in the off or stand by position the room temperature and time only will be displayed 2 The heater must be turned off at its switch l...

Page 7: ...and minutes AM or PM The time is displayed when the thermostat is on or off Displays the current day of the week The day is displayed when the thermostat is on or off Displays the current temperature C is the default but F is available The temperature range is 7 C to 32 C When the thermostat is on the programmed set temperature will be displayed When the thermostat is off only the room temperature...

Page 8: ... 2 or more seconds when thermostat is off Indicates the programming mode must press and hold for 2 or more seconds when thermostat is off Functions Button Function Description PWR OK UP DOWN PWR UP DOWN OK Switches the thermostat on If the thermostat is off pressing and releasing the PWR and OK button together will turn the thermostat on to the most recently selected working mode On Accepts the cu...

Page 9: ... set Page 8 Note Use the outer edge of buttons to toggle through functions With the thermostat off press and hold the T button for 2 seconds or longer to initiate programming the time Time the hour setting and the AM PM will flash Page 11 Setting the period starting time The hour and AM PM settings will now flash To set the P1 starting time press and release the UP and DOWN button to increase or d...

Page 10: ...fan speed may be adjusted up or down similar to operating in manual mode However whenever the thermostat changes to a new time period the temperature will be reset automatically according to that period s setting Page 9 Programming Each day of the week can be programmed individually for periods P1 P2 P3 and P4 making a total of 28 programmed periods Alternatively a weekday program can be set so th...