32 | SAMLEX AMERICA INC.
APPENDIX A
PoWeR SAVinG:
Enable or disable Power Saving Mode when in "Inverting Mode".
SELECT GROUP
CHARGE CURVE
SELECT GROUP
OTHER FUNCTION
POWER SAVING
0 = Disable
Up Key x 4
ò
Enter Key
ò
POWER SAVING
0 = Disable
ò
KEY IN PASSWORD
0000
Enter Key
ò
Password 8052
See Section 4.3.1
enteR Point:
If the value of power drawn by AC load falls to the "ENTER POINT" value for 5 sec, the unit
will enter "Power Save Mode".
SELECT GROUP
CHARGE CURVE
SELECT GROUP
OTHER FUNCTION
ENTER POINT
6W
POWER SAVING
1 = Enable
Up Key x 4
ò
Enter Key
ò
Up Key x 1
ò
ENTER POINT
06W
ò
KEY IN PASSWORD
0000
Enter Key
ò
Password 8052
See Section 4.3.1
EVO-2212, 2224 - 6W
EVO-3012, 4024 - 8W
WAKe UP Point:
If the unit is in "Power Save Mode" and the value of the AC power of the load rises to "WAKE
UP POINT", the unit will quit "Power Save Mode" and will start operating in full voltage
"Inverting Mode".
SELECT GROUP
CHARGE CURVE
SELECT GROUP
OTHER FUNCTION
WAKE UP POINT
7W
POWER SAVING
1 = Enable
Up Key x 4
ò
Enter Key
ò
Up Key x 2
ò
WAKE UP POINT
07W
ò
KEY IN PASSWORD
0000
Enter Key
ò
Password 8052
See Section 4.3.1
ReMote SWitCH:
This selection is used when ON/OFF control of EVO
TM
Inverter/Charger is desired through
external 12 VDC signal fed to Remote ON/OFF terminals on the Front Panel of EVO
TM
Inverter/
Charger (15, Fig 2.1 in EVO
TM
Inverter/Charger Owner's Manual) On/Off Logic Diagram is
shown in Fig 4.8 below:
0 = Button Type:
12VDC signal is fed through Push Button Type of Switch.
•
Momentary contact of Push Button > 2 sec will switch EVO Inverter Charger ON
1 = Switch Type:
1
st
12VDC input
> 2 sec will switch ON
EVO Inverter Charger
After power ON,
12VDC input < 5 sec
will have no effect
After power ON,
12VDC input > 5 sec
will switch OFF
EVO Inverter Charger
12VDC input is
available - Power On
No 12VDC input
for 2 sec - Off
Fig 4.8. on/off Logic Diagram for Remote Switch options
!
CAUtion!
On/Off Logic shown in Fig 4.8 also controls the operation of the On/Off Button on the front
panel of EVO
TM
Inverter/Charger (11, Fig 2.1 in EVO
TM
Inverter/Charger Owner's Manual). The
Default Setting is "Button Type".
SECtION 4 |
Parameter Setup