26 | SAMLEX AMErICA INC.
3.1 SAFety oF inStALLAtion
wArning!
Please ensure safety instructions given under Section 1 are strictly followed.
Attention!
Se il vous plaît assurer consignes de sécurité fournies à la section 1 sont strictement suivies.
3.2 oVerALL DiMenSionS
The overall dimensions and the location of the mounting holes are shown in fig. 3.1.
3.3 Mounting oF the unit
In order to meet the regulatory safety requirements, the mounting has to satisfy the following
requirements:
• Mount on a non-combustible material
• The mounting surface should be able to support a weight of at least 60 Kg / 132 lbs.
Use 4 pcs of 1/4" or M6 mounting bolts and lock washers
• Installation on marine craft and vessels will require use of Drip Shield on top of the unit to
protect against ingress of water dripping from top. Drawing of Drip Shield is given at fig
3.1(a). Configurations using the Drip Shield are shown under "Mounting Orientation".
Cooling:
The unit has openings on the front, bottom and back for cooling and ventilation. Ensure
that these openings are not blocked or restricted. Install in cool, dry and well ventilated area.
SECTIOn 3 |
Installation
426
380
298,6
50,8
20,9
123,9
303,5
Height: 207.2
Dimensions in mm
325
13
7
Mounting Holes: 7mm/0.28”
Mounting Bolts: 1/4” or M6
7
7
Fig. 3.1 Mounting Dimensions
880 mm
720 mm
90 mm
Slope of top surface
should be minimum 115˚
115˚
Fig. 3.1(a) Dimensions of Drip Shield