SAMLEX AMERICA INC. | 35
APPENDIX A
SECTION 4 |
Parameter Setup
TABLE 4.2 CHARGING PROFILE FOR 4-STAGE ADAPTIVE CHARGING FOR EQUALIZATION
Srl
No.
Options under
Programming
Parameter
“EQUALIZE–4 STAGES”
Charging Stages
Battery Type
1
EQUALIZE – 4 STAGES
0 = No (Default Setting)
1 = Yes
1.
Stage 1 – Bulk Stage
(
See Section 5.8.2 of the attached EVO-
2212/3012/2224/4024 Owner’s Manual for details):
• Charge at constant current (CC) = the programmed value of
parameter “BULK CURRENT”
(Default value is 40A.
For details of
programming range & procedure, refer to Section 4.4.2.1)
• Transition to Absorption Stage when voltage rises to the
set value for programming parameter “ABSORP VOLTAGE”
(
Default value is 14.4V for EVO-2212/3012 and 28.8V for EVO-2224/4024.
For details of programming range & procedure, refer to Section 4.4.2.2)
2.
Stage 2 - Absorption Stage
(See Section 5.8.2 of the attached
EVO-2212/3012/2224/4024 Owner’s Manual for details):
• Charge at constant voltage (CV) = the programmed value
for parameter “ABSORP VOLTAGE”.
(
Default value is 14.4V for
EVO-2212/3012 and 28.8V for EVO-2224/4024.
For details of programming
range & procedure, refer to Section 4.4.2.2)
• Adaptive Time Algorithm:
Time in Absorption Stage is
computed automatically based on time in Bulk Stage
(See
Section 5.8.2 of the attached EVO-2212/3012/2224/4024
Owner’s Manual for details)
• Transition to Equalization Stage thereafter.
3.
Stage 3 - Equalization Stage
(Section 5.8.2 of the attached
EVO-2212/3012/2224/4024 Owner’s Manual for details):
• Charge at constant voltage (CV) = the programmed value of
parameter “EQUALIZE VOLTAGE”.
(Default value is 14.4V for EVO-
2212/3012 and 28.8V for EVO-2224/4024.
For details of programming range &
procedure, refer to Section 4.4.2.3.
• Adaptive Time Algorithm:
Time in Equalization Stage is
computed automatically based on time in Bulk Stage.
(See
Section 5.8.2 of the attached EVO-2212/3012/2224/4024
Owner’s Manual for details)
• Transition to Float Stage thereafter.
4.
Stage 4 -
This stage will be the same as the last Stage of Charging
Profile from where Equalization was started.
(For details, refer
to Table 5.2.1 under Section 5.8.2.4 of the attached EVO-
2212/3012/2224/4024 Owner's Manual)
− Lead Acid: Flooded only
!
CAUTIONS!
1. Equalize Flooded Lead Acid Batteries only.
Sealed AGM / Gel Cell types of batteries are
NOT equalized
2.
Refer to Section 5.8.2 and Fig 5.2
of the attached Manual for EVO-
2212/3012/2224/4024.
3. The Adaptive Charging Algorithm measures
the Bulk Stage Time (T0) to automatically
compute Absorption Stage Time (T1') and
Equalization Stage Time (T2). This algorithm
is fully effective only when there are no
other external DC loads being supplied by
the battery that may divert full or part of
the BULK CURRENT resulting in undesired
increase in Bulk Stage Time “(T0)” and
consequently, undesired increase of
Absorption Stage Time (T1') and Equalization
Stage Time (T2).
Hence, disconnect all other
external DC loads on the battery during the
equalization cycle.
!
ATTENTIONS!
1. Égaliser les batteries au plomb inondées
seulement. Les batteries scellées de type
AGM / cellules au gel ne sont pas égalisées.
2.
Se reporter à la section 5.8.2 et figure
5.2 du manuel ci-joint pour EVO-
2212/3012/2224/4024.
3. L'algorithme de charge adaptative l'essentiel
des mesures de phase (T0) pour calculer
automatiquement l'étape d'Absorption
Temps (T1') et de la péréquation, le temps
(T2). Cet algorithme n'est pleinement
efficace que lorsqu'il n'y a pas d'autres
charges c.c. externe alimenté par la
batterie qui peut détourner tout ou
partie de l'ACTUEL EN VRAC résultant
en une augmentation indésirable en vrac
temps Étape "(T0)" et par conséquent,
augmentation indésirable de l'étape
d'Absorption Temps (T1') et de la
péréquation le temps (T2). P
ar conséquent,
déconnectez toutes les autres charges CC
externes sur la batterie pendant le cycle
d'égalisation.