42 | SAMLEX AMERICA INC.
APPENDIX A
SECTION 4 |
Parameter Setup
3-Stage Adaptive Charging Profile option “0 = 3 Stage Adaptive
(Shown as “0=3 Stg Adaptive” in the programming
screen)
” is the default charging profile applicable for Lead Acid Batteries
Details of the 6 programmable charging profiles under programming parameter “CHARGING PROFILE” are given in
TABLE 4.3 below.
!
CAUTION!
The Battery Management System (BMS) that comes with the type of Lithium Ion Battery being used
will need to have control over charging and discharging of the battery. For this, any of Pins 1/2/3/4
and 5/6/7/8 of the Temperature Sensor Jack (6, Fig 4.1 / Pinout at Fig 3.13 in the attached EVO-
2212/3012/2224/4024 Owner’s Manual ) may be used to feed potential free contact closing signal
from the BMS to “Stop Charging” or “Stop Inverting”
[Refer to Section 4.4.2.22.2 for details]
!
ATTENTIONS!
Le système de gestion de la batterie (BMS) fourni avec le type de batterie au lithium-ion utilisé
doit pouvoir contrôler la charge et le déchargement de la batterie. Pour cela, l’un des broches
1/2/3/4 et 5/6/7/8 de la prise du capteur de température (6, Fig 4.1 / Pinout à la Fig 3.13 dans le
manuel d’utilisation EVO-2212/3012/2224/4024 fourni) ) peut être utilisé pour alimenter le signal
de fermeture de contact libre de potentiel du système de management jusqu'à "Stop Charging"
ou "Stop Inverting"
[Voir la section 4.4.2.22.2 pour plus de détails]