APPENDIX A
3.1 NAVIGATING THE REMOTE
The EVO-RC provides menu items and adjustable settings to configure your EVO
™
Inverter/Charger to your specific
parameters. Please refer to the layout at Fig 1.1.
• LCD Display (1)
– The 2-line (16 characters each) LCD display shows status and information for the EVO
™
Inverter/Charger. All Setup Menus and faults also appear on the LCD display.
• ON/OFF Key (2)
– The ON/OFF Key is used for switching ON/switching OFF the EVO
™
Inverter/Charger.
• Navigation Keys (5, 6, 7, 8)
– These four Keys allow simple access to menu items that assists configuring,
monitoring, and troubleshooting the EVO
™
Inverter/Charger.
o
Navigation Key Functions:
•
Back –
Return to previous selection
•
Up –
Scroll to higher Screen Nos. / Parameter Group Nos. in various Menu Maps
•
Down –
Scroll to lower Screen Nos. / Parameter Group Nos. in various Menu Maps
•
Enter –
Enter the selected option
• Status
– Green LED indicator for indicating operating status
(See details at Section 6, Table 6.1)
• Alarm (Fault)
– Red LED indicator for indicating fault conditions
(See details at Section 6, Table 6.1)
• SD Card socket
– This slot supports SD memory card (up to 16GB; FAT 16/32). The SD Card is used for (i) Data
logging of EVO
™
Inverter/Charger's operational statistics and events and (ii) Saving and uploading of programmed
parameters
(See Section 5: SD Card)
3.2 POWER ON / POWER OFF
i
INFO
a) Minimum battery voltage required for initiating manual switching ON of the unit
is as follows:
• 12V units ----- Higher than 9V
• 24V units ---- Higher than 18V
b) Please note that this unit is designed to POWER ON AUTOMATICALLY if (i) AC voltage of 70V ±
5 VAC is available at the AC Input Terminals and (ii) DC input voltage is > 12V for 12V versions of
EVO™ and >24V for 24V versions of EVO™. If the AC input voltage and frequency are within the
programmed limits, the unit will automatically operate in “Charging Mode”. If the AC input voltage
and frequency are not within the programmed limits, the unit will operate in “Inverting" Mode.
Further, as long as AC input voltage > 70 ± 5 VAC is present, the unit CANNOT BE POWERED OFF using
the ON / OFF Button on the front panel of the unit or on the Remote Control EVO-RC. Switch OFF the
AC input first if the unit is required to be powered off. However, if the unit is in “Fault Mode”, it will
be possible to power OFF the unit with the help of the ON/OFF Push Button.
c) Before proceeding, confirm that the unit is NOT in "Standby" Mode. If it is in "Standby Mode",
the "Status" LED (3, Fig 1.1) will flash once every 5 sec and the LED screen will display one of the
"Standby Mode" Screens show in Figs 3.2 (Column 2, GROUP 1). Press the On/Off Push Botton (2, Fig
1.1) on the EVO-RC to exit the "Standby Mode" to the current operating mode. Refer to Section 3.4
for more details on "Standby Mode".
SECTION 3 |
Operation