SAMLEX AMERICA INC. | 57
SECTION 10 |
Programming of Operating Parameters
10.2.1.5 “e. Buzzer Setup”: A Buzzer has been provided to attract attention when the unit sees any one
or combination of 6 types of alarm and fault conditions. Options and Default settings are shown below.
Default setting is “Enabled” for all the 6 conditions which means that the Buzzer will be switched ON if
any one of the 6 alarm / fault condition is seen.
Parameter
Fault / Alarm
Options
Default
e. Buzzer setup
1. Fan Fault
Enabled
Enabled
Disabled
2. OV Alarm
(OV: Over Voltage)
Enabled
Enabled
Disabled
3. UV Alarm
(UV: Under Voltage)
Enabled
Enabled
Disabled
4. Overload
Enabled
Enabled
Disabled
5. Overtemp
(Over Temperature)
Enabled
Enabled
Disabled
6. Short
(Short Circuit)
Enabled
Enabled
Disabled
10.2.1.6 “f. Relay Setup”: An internal SPDT Relay ( Contact rating 240VAC, 16A) has been provided for
signaling of any one or combination of 6 types of alarm and fault conditions. Options and Default settings
are shown below. Default setting is “Enabled” for all the 6 conditions which means that the relay will be
energized if any one of the 6 alarm / fault condition is seen.
Relay contacts are accessible through 3 terminals marked NO (Normally Open), COM Common and NC
(Normally Closed) in the 7-Way Terminal Block at the back of the unit (12, Fig 6.2).
Parameter
Fault / Alarm
Options
Default
f. Relay setup
1. Fan Fault
Enabled
Enabled
Disabled
2. OV Alarm
(OV: Over Voltage)
Enabled
Enabled
Disabled
3. UV Alarm
(UV: Under Voltage)
Enabled
Enabled
Disabled
4. Overload
Enabled
Enabled
Disabled
5. Overtemp
(Over Temperature)
Enabled
Enabled
Disabled
6. Short
(Short Circuit)
Enabled
Enabled
Disabled