2 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 3
SECTION 1 |
Safety Instructions
1.1 SAFETY SYMBOLS
The following safety symbols will be used in this manual to highlight safety
and information:
WARNING!
Indicates possibility of physical harm to the user in case of non-compliance.
!
CAUTION!
Indicates possibility of damage to the equipment in case of non-compliance.
i
INFO
Indicates useful supplemental information.
Please read these instructions before installing or operating the unit to prevent personal
injury or damage to the unit.
1.2 SAFETY INSTRUCTIONS - GENERAL
1.2.1 Installation and wiring compliance
• Installation and wiring must comply with the Local and National Electrical Codes and
must be done by a certified electrician.
1.2.2 Preventing electrical shock
• Always connect the grounding connection on the unit to the appropriate grounding
system.
• Disassembly / repair should be carried out by qualified personnel only.
• Disconnect all AC and DC side connections before working on any circuits associated
with the unit. Turning the ON/OFF switch on the unit to OFF position may not entirely
remove dangerous voltages.
• Be careful when touching bare terminals of capacitors. Capacitors may retain high le-
thal voltages even after the power has been removed. Discharge the capacitors before
working on the circuits.
1.2.3 Installation environment
• The inverter should be installed indoor only in a well ventilated, cool, dry
environment.
• Do not expose to moisture, rain, snow or liquids of any type.
• To reduce the risk of overheating and fire, do not obstruct the suction and discharge
openings of the cooling fan.
• To ensure proper ventilation, do not install in a low clearance compartment.
1.2.4 Preventing fire and explosion hazards
• Working with the unit may produce arcs or sparks. Thus, the unit should not be used
in areas where there are flammable materials or gases requiring ignition protected