50 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 51
The inverter will switch ON when the external relay contact / switch is closed [External DC
voltage (10-33VDC) is fed to terminals marked "+" and "–" on the 3-Way Terminal Block
(4A, Fig 6.1)]. The inverter will switch OFF when the external relay contact / switch is
opened [External DC voltage (10-33VDC) is removed from terminals marked "+" and "–"
on the 3-Way Terminal Block (4A, Fig 6.1)].
8.9.1.3 1-Wire ON/OFF Control Using Switched DC Voltage from the Battery Supplying the
Inverter, Fig 8.2(c) :
!
CAUTION!
1. Please ensure correct polarity of wiring connection. Positive (+) of the exter-
nal DC source should be connected to the Positive terminal marked "+" on
the 3-Way Terminal Block (4A, Fig 6.1) and the Negative Terminal (
–
) of the
external DC source should be connected to the Negative Terminal marked
"
–
" on the 3-Way Terminal Block (4A, Fig 6.1). In case the polarity is reversed,
the ON/OFF control will NOT operate. The input to these terminals is pro-
tected against reverse polarity.
2. Use 1A fuse as shown as close to the DC source as possible.
!
ATTENTION!
1. Veuillez vous assurer que la polarité de la liaison de câblage. La borne
positive ( +) de la source de courant continu externe doit être connecté à la
borne positive marquée " +" ; sur le bornier à 3 contacts (4A, figure 6.1) et
la borne négative (-) de la source de courant continu externe doit être con-
necté à la borne négative marquée "-" ; sur le bornier à 3 contacts (4A, Fig.
6.1). Au cas où la polarité est inversée, le contrôle ON/OFF ne fonctionne
pas. L'entrée à ces bornes est protégé contre les inversions de polarité.
2. Utilisez un fusible 1A comme indiqué aussi près que possible de la source CC
The inverter will switch ON when the external relay contact / switch is closed [Positive (+)
voltage from the 12V or 24V battery supplying the inverter is fed to terminal marked "+"
of the Terminal Block (4A, Fig 6.1)]. The inverter will switch OFF when the external relay
contact / switch is opened [Positive "+" voltage from the 12V or 24V battery supplying the
inverter DC voltage is removed from the terminal marked "+" on the 3-Way Terminal Block
(4A, Fig 6.1)]. In a 12V vehicle / RV, the +12V control voltage may be fed directly from
the Ignition Switch. This will switch ON the inverter when the Ignition is ON and switch
OFF the inverter when the Ignition is switched OFF.
SECTION 8 |
Installation