background image

1. Important Safety Information 

WARNING!

Before installing and using the Inverter, you need to read 
following safety information carefully.

1-1. General Safety Precautions 

1-1-1. Do not expose the Inverter to water, mist, snow, or dust.  To reduce the 

risk of hazard, do not cover or obstruct the ventilation shaft. 

Do not install the Inverter in a zero-clearance compartment.  

Overheating may occur. 

1-1-2. To avoid the risk of fire and electronic shock, make sure that existing 

wiring is in good electrical condition and not undersize. 

Do not operate the Inverter with damaged or substandard Wiring. 

1-1-3. There are some components in the inverter can cause arcs and sparks. 

To prevent from fire or explosion, do not put batteries, flammable 

materials, or anything should be ignition–protected around the inverter. 

1-2. Precautions When Working with Batteries 

1-2-1. If battery acid contacts your skin or clothing, you need to wash it out 

immediately with soap and water.  If acid enters into your eyes, 

immediately flush your eyes with running cold water for at least 20 

minutes and get medical attention immediately.

1-2-2. Never smoke or make a spark or flame in the vicinity of batteries or 

Engines.

1-2-3. Do not drop a metal tools on the battery.  The resulting spark or short-

circuit on the battery or other electrical parts may cause an explosion. 

1-2-4. Remove personal metal items such as rings, bracelets, necklaces, and 

watches when working with a lead-acid battery, 

A lead-acid battery may produce a short-circuit current who’s 

temperature is high enough to weld these metal items and cause a 

severe burn. 

1

Summary of Contents for SA-150-112

Page 1: ...SA 150 SA 300 Series Pure Sine Wave Inverter User s Manual ...

Page 2: ...ical Performance 300W 3 2 3 Mechanical Drawing 150W 4 2 4 Mechanical Drawing 300W 5 3 Instructions 6 3 1 Front Panel Operation 6 3 2 Rear Panel Operation 6 3 3 AC Safety Grounding 7 3 4 Installation 8 3 5 DC Input Outlet sockets available 9 3 6 AC Output Outlet sockets available 9 3 7 ON OFF REMOTE Main Switch 10 4 Troubleshooting 11 5 Maintenance 12 6 Warranty 12 1 ...

Page 3: ...n do not put batteries flammable materials or anything should be ignition protected around the inverter 1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts your skin or clothing you need to wash it out immediately with soap and water If acid enters into your eyes immediately flush your eyes with running cold water for at least 20 minutes and get medical attention immediately...

Page 4: ... Allowed cosθ 90 cosθ 90 Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Remote Control Yes On Off controlled by external switch Safety Certification UL458 EN60950 1 EMC FCC Class B EN55022 1997 EN61000 3 2 1998 EN61000 3 3 1995 EN55024 2001 e mark e13 022025 Operating Temperature 0 40 Storage Temperature 30 to 70 Fan Cooling Thermostatically contr...

Page 5: ...wed cosθ 90 cosθ 90 Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Remote Control Yes On Off controlled by external switch Safety Certification UL458 EN60950 1 EMC FCC Class B EN55022 1997 EN61000 3 2 1998 EN61000 3 3 1995 EN55024 2001 e mark e13 022078 Operating Temperature 0 40 Storage Temperature 30 to 70 Fan Cooling Thermostatically controlled...

Page 6: ...2 3 Mechanical Drawing 4 ...

Page 7: ...2 4 Mechanical Drawing 5 ...

Page 8: ...tallation 3 1 2 LED display indicates Power Status LED Conditions Status Solid Green AC Power OK Fast Red Blink OVP Slow Red Blink UVP Intermittently Red Blink OTP Solid Red OLP 3 1 3 Remote Port Place 0 75mm2 and Screw type cable between the remote port and the panel 3 2 Rear Panel Operations 3 2 1 Ventilation shaft Keep the ventilation shaft a distance at least 3 inch from anything surrounding i...

Page 9: ...ctor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation This conforms to National Electrical Code requirements that separately derived from AC sources such as inverters and generators which have their neutral conductors tied to ground in the same way as the neutral conductors from the utility tied to ground at the AC breaker panel For...

Page 10: ...ments are checked OK and satisfied and all connections are made it s time to turn on the inverter by switching the power to I position The sine wave filters provide sine wave output voltage when driven from AC outlet To save the battery power you are highly recommended to turn off the inverter when it is not used DC input voltage status as follows Model DC Input Over Voltage DC Input Under Voltage...

Page 11: ... available CIGARETTE CLAMP STRIPPED WIRE POWER CLAW PP45 3 6 AC output Outlet Sockets available Australia New Zealand IEC 2 Universal HARD WIRE United Kingdom North America GFCI IEC 1 NEMA 5 15R NEMA 5 20R Continental European 9 ...

Page 12: ...t be OFF 3 7 2 Before using the remote unit make sure the main switch must be REMOTE 3 7 3 Ensure the remote control contact is off 3 7 4 Remote Port Place 0 75mm2 and Screw type cable between the remote port and the panel 3 7 5 Remote port ON OFF inverter setup status REMOTE PORT MODE Ⅰ MODE Ⅱ 10 ...

Page 13: ...fast Over input voltage Check input voltage Reduce input voltage b Power status light is blinking red slowly Low input voltage Recharge battery Check connections and cable c Power status light is blinking red intermittently Thermal shutdown Improve ventilation Make sure ventilation shafts in the inverter are not obstructed Lower ambient temperature d Power status light is glowing red steadily Shor...

Page 14: ...product against defects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective power inverters if you directly returned them to us with postage paid Please note that Samlex is only responsible for ensuring our products are operational before delivering This warranty will be considered void if the unit has been misused altered or ac...

Page 15: ... 110 17 Fawcett Road Coquitlam BC V3K 6V2 Canada Toll free phone 1 800 561 5885 Toll free fax 1 888 814 5210 General Inquiries samlex samlexamerica com WWW http www samlexamerica com 034_2009_SA 150_SA 300_Manual_Dec2009 ...

Reviews: