Place the back connector. Fix the back connector with M2.5 screw.

1. Mass

2. Power switch

3. The socket

4. Connections for back connectors

Rear side view

SRU REAR SIDE

DO NOT INSERT SHARP METAL OBJECTS OR FINGERS INTO THE SPACE BEHIND 

THE POWER PANEL!

THE  SIGN  “LIGHTNING  IN  A  TRIANGLE”  IS  TO  ALERT  THE  USER  TO  THE 

PRESENCE OF LIFE-THREATENING HIGH POWER.

LABEL IS PLACED NEXT TO POWER PANEL.

HIGH VOLTAGE!

DANGER!

Summary of Contents for DAA-104

Page 1: ...08 april 2013 Updated 03 july 2014 Z10 3 edition 1 Code 001 103 001 108 007 159 007 160 007 161 ENGLISH Sams elektronik d o o 48 Zivka Davidovica st 11050 Belgrade Serbia Tel Fax 381 11 3806 253 381 11 2402 212 sams sams rs www sams rs USER MANUAL FOR USE AND MAINTENANCE Read the instructions before using the device Keep this manual for periodic usage ...

Page 2: ...ufacturer servicer has not completed repair or replacement within a reasonable time or if the manufacturer servicer did not perform repair or replacement without significant inconvenience to the consumer 5 The consumer may not terminate the contract if the lack of conformity of the product is negligible 6 The product will function properly when used in accordance with the user manual 7 Period of s...

Page 3: ...upplied with the device SAFETY WARNINGS FOR SRU RACK FRAME ELECTRICAL SHOCK HAZARD DO N OT O PEN CAUTION RIZIK OD S TRUJNOG UDARA NE O TVARATI DOK JE P OD N APONOM UPOZORENJE CLASS I DEVICE Grounding is connected to the chassis of the device The power supply is protected with fuse against overload DECLARATION OF CONFORMITY for product SRU RACK FRAME WITH POWER SUPPLY PSU 212 WITH CORRESPONDING MOD...

Page 4: ...s device is equipped with a protective fuse in the power outlet Do not bypass fuse 12 Do not replace the fuse Replacement can be made by a person authorized by the manufacturer 13 Do not bend the power cord so that it can be damaged 14 Connect connectors as in the enclosed instructions Deviations from the allowed values predicted for the inputs and outputs of the device can cause severe damage and...

Page 5: ...fiers UNPACKING AND INSTALLATION 6 MAINTENANCE 6 REMOVAL AND STORAGE 6 DESCRIPTION 7 MODULE INSTALATION IN SRU RACK FRAMES 12 BACK CONNECTORS 14 SRU REAR SIDE 15 BLOCK DIAGRAM 16 PCB WITH THE LAYOUT OF ELEMENTS 16 INSTALLATION STANDALONE 17 NOTES 18 Page Description TABLE OF CONTENTS ...

Page 6: ...authorized by Sams elektronik doo Any voluntarily opening device upgrading or servicing is strictly prohibited and is subject to warranty void and the possibility of injury Places for fastening PROCEDURES FOR SAFE USE OF THE DEVICE 1 If the device is not supplied with SRU rack frame remove the protective wrap from the device If the device is supplied with SRU rack frame remove the protective wrap ...

Page 7: ...mpatible Connector 3 pin terminal strip Impedance 75Ω Max level 7V p p Min level 0 2V p p AES3 110Ω OUTPUT Connector 3 pin terminal strip Impedance 110Ω Nominal level 3 1V p p 10 Rising time 4ηs to 31ηs Symmetry 30dB DC at 6MHz Jitter 0 005UI at 700Hz 10KHz AES3 id 75Ω OUTPUT Connector 3 pin terminal strip Impedance 75Ω Nominal level 1V p p 10 Rising time 30ηs to 40ηs Jitter 0 005UI at 700Hz 10KHz...

Page 8: ...mpatible Connector 3 pin terminal strip Impedance 75Ω Max level 7V p p Min level 0 2V p p AES3 110Ω OUTPUT Connector 3 pin terminal strip Impedance 110Ω Nominal level 3 1V p p 10 Rising time 4ηs to 31ηs Symmetry 30dB DC at 6MHz Jitter 0 005UI at 700Hz 10KHz AES3 id 75Ω OUTPUT Connector 3 pin terminal strip Impedance 75Ω Nominal level 1V p p 10 Rising time 30ηs to 40ηs Jitter 0 005UI at 700Hz 10KHz...

Page 9: ...F compatible Connector BNC Impedance 75Ω Max level 7V p p Min level 0 2V p p AES3 110Ω OUTPUT Connector 3 pin terminal strip Impedance 110Ω Nominal level 3 1V p p 10 Rising time 4ηs to 31ηs Symmetry 30dB DC at 6MHz Jitter 0 005UI at 700Hz 10KHz BLOCK DIAGRAM ORDERING INFORMATION Code Name Description 007 161 DAA 36 AES DA 3x 1x6 Specifications and designs are subject to change without notice DAA 3...

Page 10: ...IF compatible Connector BNC Impedance 75Ω Max level 7V p p Min level 0 2V p p AES3 110Ω OUTPUT Connector XLR or 3 pin terminal strip Impedance 110Ω Nominal level 3 1V p p 10 Rising time 4ηs to 31ηs Symmetry 30dB DC at 6MHz Jitter 0 005UI at 700Hz 10KHz BLOCK DIAGRAM ORDERING INFORMATION Code Name Description 007 160 DAA 26 AES DA 2x 1x6 Specifications and designs are subject to change without noti...

Page 11: ...PDIF compatible Connector BNC Impedance 75Ω Max level 7V p p Min level 0 2V p p AES3 110Ω OUTPUT Connector XLR or 3 pin terminal strip Impedance 110Ω Nominal level 3 1V p p 10 Rising time 4ηs to 31ηs Symmetry 30dB DC at 6MHz Jitter 0 005UI at 700Hz 10KHz BLOCK DIAGRAM ORDERING INFORMATION Code Name Description 007 159 DAA 16 AES DA 1x6 Specifications and designs are subject to change without notic...

Page 12: ...N IN SRU RACK FRAMES Make sure that the module is set to the correct place in relation to the back connector BEFORE INSTALLING OR REMOVING THE MODULE FROM SRU ALWAYS TURN OFF THE POWER Lock module with lever to the position NOTE NEVER PLACE MODULE TO PLACE OF THE POWER SUPPLY MODULE The label that indicates the place for power supply module FOR POWER SUPPLY ONLY WARNING ...

Page 13: ...ams sams rs www sams rs elektronik 13 Distribution amplifiers 1 2 3 1 The module set between the guides not metal plate 2 Locking lever mount behind the groove 3 Push the lever to lock in an upright position The module is locked ...

Page 14: ... 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 IN G DAA 104 G AUDIO OUT 1 G AUDIO OUT 2 G AUDIO OUT 3 G AUDIO OUT 4 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 DAA 106 BACK CONNECTORS 1 AUDIO INPUT balanced 2 AUDIO OUTPUTS balanced Unbalancing audio outputs Be sure to install a...

Page 15: ... 5 screw 1 Mass 2 Power switch 3 The socket 4 Connections for back connectors Rear side view SRU REAR SIDE DO NOT INSERT SHARP METAL OBJECTS OR FINGERS INTO THE SPACE BEHIND THE POWER PANEL THE SIGN LIGHTNING IN A TRIANGLE IS TO ALERT THE USER TO THE PRESENCE OF LIFE THREATENING HIGH POWER LABEL IS PLACED NEXT TO POWER PANEL HIGH VOLTAGE DANGER ...

Page 16: ...of the impedance of the input signal 110Ω 75Ω Set the jumper for 75Ω 5 The choice of the impedance of the output signal set jumper to position 2 3 75Ω 1 2 110Ω JMP4 1 output JMP3 2 output JMP6 3 output JMP5 4 output JMP8 5 output only on DAA 106 JMP7 6 output only on DAA 106 Adapter cable for the transition from XLR to BNC RCA respectively 110Ω 75Ω On board place jumper from 110Ω to 75Ω 5 1 2 110Ω...

Page 17: ... the device by pressing switch If everything is OK LEDs will illuminate LOCK the presence of an incoming signal POWER Power indicator 1x6 AES EBU distribution amplifier 3x DAA 36 www sams rs POWER LOCK AUDIO 1 POWER LOCK AUDIO 2 POWER LOCK AUDIO 3 POWER FUSE 500mA AC 230V 50Hz AUDIO OUTPUT 3 INPUT 3 G G G G G G G G G 1 2 3 4 5 6 AUDIO OUTPUT 2 INPUT 2 G G G G G G 1 2 3 4 5 6 AUDIO OUTPUT 1 INPUT 1...

Page 18: ...DAA elektronik Sams elektronik d o o sams sams rs www sams rs 18 Distribution amplifiers NOTES ...

Reviews: