3. Insert new seal (5.5) into the flanged
section. Slide valve bonnet over the plug
stem extension and place it on the
flanged section.
4. Thread on nut (5.3) and screw tight, ob-
serving the tightening torques in Table 1.
5. Apply lubricant (order no. 8150-0116)
to packing parts and threaded bushing
(5.2).
Slide spring (4.1), washer (4.3), and
new packing rings (4.2) over the plug
stem extension into the packing cham-
ber.
Put on threaded bushing (5.2) and
tighten it as far as it will go.
6. Screw the lock nut (6.2) and nut (6.1)
loosely onto the plug stem extension
(6.3).
7. Mount actuator and adjust the lower or
upper bench range as described in sec-
tion 2.
6
Version with split plug stem
extension
To keep the overall height of the valve as
small as possible for transportation purposes
in cold-box installations, the actuator and
valve bonnet must be removed from the
flanged section of the cryogenic extension
bonnet and protected by a protective cap
and a stopper.
If these measures have not been undertaken
prior to delivery, proceed as follows:
The special tool (order no. 1280-3031,
Fig. 4) is required for assembly and reas-
sembly. Only the use of this tool guarantees
that the metal bellows will not be damaged.
EB 8093 EN
11
Version with split plug stem extension
Fig. 4 · Mounting the protective cap
5.3
Nut
6.3b Plug stem extension
(bottom section)
20
Nut
Special tool
with 17 and 24 mm
socket wrench
22
Nut
23
Protective cap
24
Seal
25
Stopper
Summary of Contents for 3248-1
Page 14: ...14 EB 8093 EN...
Page 15: ...EB 8093 EN 15...