background image

Disassembly:

Important!

For actuators with fail-safe action "Actuator
stem extends" and especially actuators with
pretensioned springs, apply a pressure be-
forehand to retract the actuator stem slightly.

1. Remove clamps of the stem connector (7)

between actuator stem and plug stem
and unscrew annular nut (8.2).

2. Lift the actuator off the valve.
3. Place a wrench at the stem connector nut

(6.1) to hold it stationary and loosen the
lock nut (6.2). Unscrew stem connector
nut and lock nut from the plug stem ex-
tension (6.3a).

Caution!

The plug stem extension may not

be twisted at all, otherwise the metal bellows
could be damaged.

4. Unthread guide bushing (5.2) to relieve

the tension from the packing (4.2).

5. Unthread nuts (5.3) at the valve bonnet.

Lift valve bonnet (5) carefully upwards
off the flange of the cryogenic extension
bonnet (1.1).

6. Place the special tool with 24 mm socket

wrench over the plug stem extension
(6.3b) onto the nut (20) in such a way
that the labeling "disassem-

ble/demontieren" faces upwards. (As
the needle bearing of the tool can only
be turned in one direction, it must be
placed turned by 180° as required for
assembly or disassembly.)
Insert 17 mm socket wrench and un-
screw the top section of the plug stem
extension (6.3a) with socket wrench.

7. In case of DN 100 and 150 (NPS 4 and

6), unscrew nut (20). In case of DN 25
to 80 (NPS 1 to 3) the nut remains on
the plug stem extension.

8. Insert seal (24) and fit on protective cap

(23).

9. Apply lubricant (order no. 8150-0116)

to the protruding thread of the plug stem
extension to prevent dirt and moisture
from entering the plug stem extension.

10. Screw on nut (22) and hand tighten to

extract the plug stem extension to the di-
mension

h (Table 2). Do not tighten

more than 10 Nm, otherwise the metal
bellows will be damaged.

11. Tighten nut (5.3) (tightening torque in

Table 2).

12. Insert stopper (25).

12

EB 8093 EN

Version with split plug stem extension

Table 2

Version with split plug stem extension

Nominal size

Tightening torque Nm

Dimension h

Nut (22)

Nut (5.3)

Plug stem extension (6a)

mm/inch

DN

NPS

Class 150/300/600

15 to 80

1 to 3

Max. 10

(hand tight)

30

50

15/ 0.6

100/150

4 to 6

50

80

26/1.0

Summary of Contents for 3248-1

Page 1: ...ol Valve Type 3248 1 and Type 3248 7 Mounting and Operating Instructions EB 8093 EN Edition September 2008 Fig 1 Type 3248 as globe pattern valve and angle pattern valve both fitted with Type 3277 Pne...

Page 2: ...ce 8 5 1 Replacing packing seat and plug 9 6 Version with split plug stem extension 11 7 Customer inquiries 13 2 EB 8093 EN Contents Note Non electrical actuators and valves do not have their own pote...

Page 3: ...he order The manufacturer does not assume any responsibility for damage caused by external forces or any other external influence 4 Any hazards which could be caused in the control valve by the proces...

Page 4: ...V ring packing 4 2 Fail safe position Depending on how the springs 8 3 are ar ranged in the actuator the control valve as sumes two different fail safe positions Actuator stem extends When the pressur...

Page 5: ...nd principle of operation Fig 2 Sectional drawings Top section 6 3a Nut Bottom section 6 3b Version with split plug stem extension refer to section 6 Type 3271 Actuator Type 3277 Actuator Globe valve...

Page 6: ...sion 4 Place the actuator on the valve bonnet 5 and screw tight using the annular nut 8 2 5 Read the nameplate on the actuator to determine which bench range signal range with pretensioned springs and...

Page 7: ...range of 0 2 to 1 bar the springs are to be pretensioned by 0 1 bar for example the bench range is shifted by 0 1 bar to 0 3 bar When adjusting the valve a signal pressure of 0 3 bar is to be set as...

Page 8: ...e of the bottom dia phragm case 4 Operation To reverse the direction of action refer to Mounting and Operating Instructions of the respective pneumatic actuator EB 8310 EN for Type 3271 and EB 8311 EN...

Page 9: ...between actuator stem and plug stem and unscrew annular nut 8 2 2 Lift the actuator off the valve Caution To avoid damaging the metal bellows make sure that no torque is transmitted to the bellows we...

Page 10: ...Check that both washers 6 8 are still in the plug stem extension Screw the plug stem tightly into the plug stem extension Tightening torque 50 Nm with DN 25 to 80 and 80 Nm with DN 100 to 150 Seat If...

Page 11: ...escribed in sec tion 2 6 Version with split plug stem extension To keep the overall height of the valve as small as possible for transportation purposes in cold box installations the actuator and valv...

Page 12: ...sem ble demontieren faces upwards As the needle bearing of the tool can only be turned in one direction it must be placed turned by 180 as required for assembly or disassembly Insert 17 mm socket wren...

Page 13: ...in Table 2 7 Insert seal 5 5 into flanged section Slide valve bonnet carefully over the plug stem extension 6 3a to ensure that the packing does not get damaged and place it on the flanged section 8 S...

Page 14: ...14 EB 8093 EN...

Page 15: ...EB 8093 EN 15...

Page 16: ...SAMSON AG MESS UND REGELTECHNIK Weism llerstra e 3 60314 Frankfurt am Main Germany Phone 49 69 4009 0 Fax 49 69 4009 1507 Internet http www samson de EB 8093 EN S Z 2008 09...