DIAGNOSIS_DATA_1 (131)
Storage class: – · Read capability (r)
Diagnostic alarms
• 0x01 Inconsistent data memory
• 0x02 Potentiometer parameter
• 0x04 Calibration parameter
• 0x08 General parameter
• 0x10 Interal device error
• 0x20 PA parameter
• 0x40 Info parameter
• 0x80 Options parameter
DIAGNOSIS_DATA_2 (132)
Storage class: – · Read capability (r)
Diagnostic alarms
• 0x01 Diagnostic parameters
DIAGNOSIS_EXT (60)
Storage class: – · Read capability (r)
Further detailed information of the device, coded bitwise. More than one alarm possible at one time.
Bit: 0 = false · 1 = true
Byte
Bit
Description
0
0
Actuator springs: Perhaps spring stiffness increased (TEST)
0
1
Actuator springs: Working at full capacity
0
2
Actuator springs: Working at full capacity (TEST)
0
3
Shift of working range: Closed position
0
4
Shift of working range: Max. opening
0
5
Friction: Much higher over whole range
0
6
Friction: Much lower over whole range
0
7
Friction: Much higher over partial range
1
0
Friction: Much lower over partial range
1
1
Friction: Much higher over whole range (TEST)
1
2
Friction: Much lower over whole range (TEST)
1
3
Friction: Much higher over partial range (TEST)
1
4
Friction: Much lower over partial range (TEST)
1
5
Leakage in pneumatics: Perhaps existing (TEST)
1
6
Leakage in pneumatics: Perhaps existing
1
7
Leakage in pneumatics: Perhaps too large (TEST)
50