Repair and maintenance procedures (DIRECTIONAL VALVE)
There are several models of directional valves mounted on diaphragm pumps DF-100. Externally controlled directional valve, directional valve with
remote exhaust and normal exhaust. To identify the one you have purchased, go to the following chart with your product code, which can be found
on the nameplate of the pump, in the case externally controlled see the parts drawing for your pump on pages 12-15.
DF-100 X X X X X X X X X
Kit DIRECTIONAL VALVE normal exhaust
Kit
Pos.
Description
Cuan
Material
558350
A
1
Air inlet circlip
1
Steel
2
O-ring
1
NBR
3
Inlet adaptor
1
Steel
4
Pivoting arm
1
Elastollan Delrin
5
Distributor lower
seal
2
NBR
6
Directional valve
body DF-100
1
Aluminium
7
O-ring
1
NBR-Ptfe
8
Sealing drum
1
Elastollan Delrin
9
Bolt
1
Stainless steel
10
Muffler
1
Brass
11
Air outlet circlip
1
Steel
Kit DIRECTIONAL VALVE driven exhaust
Kit
Pos.
Description
Cuan
Material
558351
B
1
Air inlet circlip
1
Steel
2
O-ring
2
NBR
3
Inlet adaptor
1
Steel
4
Pivoting arm
1
Elastollan Delrin
5
Distributor lower
seal
2
NBR
6
Directional valve
body DF-100
1
Aluminium
7
O-ring
1
NBR-Ptfe
8
Sealing drum
1
Elastollan Delrin
9
Bolt
1
Stainless steel
11
Air outlet circlip
2
Steel
12
Outlet adaptor
1
Steel
Maintenance (to remove the pivoting arm):
1. Remove 1, 2 ,3 , 10, 11, 12
2. Remove 9
3. Remove 4, 7, 8
X