Directflo
®
: upgrading to quick coupling diaphragms
1. Please refer to the pump operation and maintenance manual and follow the
diaphragm replacement procedure to remove the diaphragms.
2. Pull out the central shaft.
3. Push in a quick coupling shaft (for stainless steel shafts, DF30 = part
855431, DF50 = part 855432, DF100 = part 855433)
4. Slide the quick coupling diaphragm adapters onto the quick coupling shaft
ends - please refer to the below illustrations.
A
B
C
D