background image

4

PS10 Guided Tour - Front Panel

1

2

3

4

PowerStrip PS10 Front Panel
1:   Circuit breaker-

 This circuit breaker will trip whenever the total load on the PS10 

(all rear panel switched outlets plus the front panel unswitched convenience 

outlet) exceeds 10 amps.  To reset it, unplug one or more devices so as to reduce 

the load and gently press the circuit breaker in until you hear it click. 

 

Note: 

It may take a minute to cool before you can reset it.

2.   Vent - 

Convection cooling is accomplished by the front panel vent holes.

3:   Unswitched convenience outlet- 

This IEC outlet is active whenever the PS10 is 

plugged in, regardless of the setting of the Outlets switch (see #4 below).

4:   Outlets switch-

 Use this to turn the rear panel outlets on or off.  When on, the 

status light inside this switch is lit red. 

Summary of Contents for PowerStrip PS10

Page 1: ...PS10 PB10 PB10PRO RACK MOUNT POWER DISTRIBUTION...

Page 2: ...cep tacles and at the point at which they exit from the unit 11 Unplug this unit during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified personnel Servicing...

Page 3: ...784 2201 www samsontech com Table of Contents Introduction 2 PowerBrite Features 3 PS10 Guided Tour Front Panel 4 PS10 Guided Tour Rear Panel 5 PB10 Guided Tour Front Panel 6 PB10 Guided Tour Rear Pa...

Page 4: ...low us to send you updated information about other Samson products in the future Also be sure to check out our website www samsontech com for complete information about our full product line With prop...

Page 5: ...ear An independent dedicated switch with status light for powering the rear panel switched outlets In the PowerBrite PB10 and PowerBrite PB10Pro dual slide out cylinders containing LED light clusters...

Page 6: ...o as to reduce the load and gently press the circuit breaker in until you hear it click Note It may take a minute to cool before you can reset it 2 Vent Convection cooling is accomplished by the front...

Page 7: ...d Heavy Duty 14 gauge mains power cord 2 Switched AC outlets Connect external equipment to these standard IECoutlets which are turned on and off from the front panel Outlets switch see 2 on the previo...

Page 8: ...to cool before you can reset it 2 Dimmer Use this to adjust the level of the LED light in the slide out Lamps 3 Lamps Contains the PB10 s 5 LED light Use the Dimmer control see 2 above to adjust the b...

Page 9: ...USB Socket USB type socket for connecting the included USB gooseneck LED lamp 3 Switched AC outlets Connect external equipment to these standard 3 pin AC outlets which are turned on and off from the f...

Page 10: ...of voltage in the electrical signal being received by the PowerBrite PB10Pro WARNING Severe voltage swings can cause damage to connected equipment If you see the voltmeter changing drastically or rapi...

Page 11: ...2 USB Socket USB type socket for connecting the included USB gooseneck LED lamp 3 Switched AC outlets Connect external equipment to these standard 3 pin AC outlets which are turned on and off from th...

Page 12: ...is lit red This activates all rear panel switched outlets 5 Turn on all connected equipment one at a time If the total load exceeds 10 amps the front panel circuit breaker will trip To reset it unplug...

Page 13: ...imately 50 times longer than incandescent ones with a typical life of 100 000 hours as opposed to incandescent lights which rarely last more than about 2 000 hours LED lights are brighter than incande...

Page 14: ...g Voltage 50 A 340 Vac Response Time 1 nanosecond Max Surge Current 6 000 Amps 8 x 20 _s pulse Max Spike Energy 70 Joules per leg Noise Attenuation 20 dB 1 5 MHz to 200 MHz Power Cord Attached 14 gaug...

Page 15: ......

Page 16: ...Samson Technologies Corp 45 Gilpin Avenue Hauppauge New York 11788 8816 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 631 784 2201 www samsontech com...

Reviews: