66
EB 8384-6S EN
Mounting and start-up
2.
Place coupling wheel (4) with flat side
facing the actuator on the follower clamp
(3). Refer to Fig. 21 to align slot so that it
matches the direction of rotation when the
valve is in its closed position.
3. Fasten the coupling wheel (4) and follow-
er clamp (3) tightly onto the actuator shaft
using screw (4.1) and disk spring (4.2).
4. Fasten the bottom pair of brackets (10.1)
with the bends pointing either facing to
the inside or to the outside (depending on
the actuator size) onto the actuator hous-
ing. Position the top pair of brackets (10)
and fasten.
5. Mount connecting plate (6) or pressure
gauge bracket (7) with pressure gauges
on the positioner, making sure the two
seals are seated properly. Double-acting
springless rotary actuators require the use
of a reversing amplifier on the connection
side of the positioner housing (see sec-
6. Unscrew the standard follower pin (2)
from the positioner's M lever (1). Use the
metal follower pin (Ø 5 mm) included in
the mounting kit and screw tight into the
hole for pin position 90°.
7. Place positioner on the top bracket (10)
and fasten tight. Taking the actuator's di-
rection of rotation into account, adjust le-
ver (1) so that it engages in the slot of the
coupling wheel (4) with its follower pin
(Fig. 21). It must be guaranteed that the
lever (1) is parallel to the long side of the
positioner when the actuator is at half its
angle of rotation.
8. Stick the scale plate (4.3) on the coupling
wheel so that the arrow tip indicates the
closed position and it can be easily read
when the valve is installed.
5.8.1 Heavy-duty version
Î
Î
Required mounting parts and accesso
-
ries: Table 7
Both mounting kits contain all the necessary
mounting parts. The parts for the actuator
size used must be selected from the mount-
ing kit.
Prepare actuator and mount possibly re-
quired adapter supplied by the actuator
manufacturer.
1. Mount the housing (10) onto the rotary
actuator. In case of VDI/VDE attachment,
1.2
1.1
1
2
4.1
4.2
5
3
Fig. 20:
Mounting the coupling wheel on
Type 3278
10
10.1
6
(7, 8)
1.1
2
4.3
5
6.1
4
1.2
1
130 mm
80 mm
NOTICE
Only use the connecting
plate (6) included in the
accessories to connect
supply and output.
Never screw threaded parts
directly into housing.
1
Lever
1.1
Nut
1.2
Disk spring
2
Follower pin
3
4
Coupling wheel
4.1
Screw
4.2
Disk spring
4.3
Scale plate
5
Actuator shaft
Adapter for Type 3278
6
Connecting plate
6.1
Seals
7
Pressure gauge bracket
8
Pressure gauge
mounting kit
10
Top pair of brackets
10.1
Bottom pair of brackets
Control valve opens counterclockwise
Control valve opens clockwise
Slot
Slot
Fig. 21:
Attachment to rotary actuators
Summary of Contents for TROVIS SAFE 3730-6
Page 12: ...12 EB 8384 6S EN...
Page 16: ...16 EB 8384 6S EN...
Page 22: ...22 EB 8384 6S EN...
Page 40: ...40 EB 8384 6S EN...
Page 42: ...42 EB 8384 6S EN...
Page 82: ...82 EB 8384 6S EN...
Page 90: ...90 EB 8384 6S EN...
Page 96: ...96 EB 8384 6S EN...
Page 132: ...132 EB 8384 6S EN...
Page 152: ...152 EB 8384 6S EN...
Page 155: ...EB 8384 6S EN 155...
Page 156: ...156 EB 8384 6S EN...
Page 157: ...EB 8384 6S EN 157...
Page 158: ...158 EB 8384 6S EN...
Page 159: ...EB 8384 6S EN 159...
Page 160: ...160 EB 8384 6S EN...
Page 161: ...EB 8384 6S EN 161...
Page 162: ...162 EB 8384 6S EN...
Page 163: ...EB 8384 6S EN 163...
Page 164: ...164 EB 8384 6S EN...
Page 165: ...EB 8384 6S EN 165...
Page 166: ...166 EB 8384 6S EN...
Page 167: ...EB 8384 6S EN 167...
Page 182: ...182 EB 8384 6S EN...
Page 183: ...EB 8384 6S EN 183...