Confidential
Chapter 3 Connecting Cables
5G NR HRU Installation Manual v1.0
102
Copyright © 2018, All Rights Reserved.
The method for connecting/disconnecting the MPO connector is as follows:
- For connecting the connector, push the shell to upper side.
- For disconnecting the connector, pull the coupling nut to lower side.
Connecting UDA Cable
To connect a UDA cable, do the following:
Prerequisites
Before proceeding with connecting the UDA cable, make sure that you have the
items mentioned in the table below:
Table 29.
Parts and Tools for Connecting UDA Cable
Category
Description
Installation Section
HRU UDA Port to External alarm device
Cable
UDA Cable Assembly (24 AWG, 5C)
Minimum Cable
bend Radius
5 × OD
Connector
External alarm device
Check specifications of external device output terminal
per site and prepare fasteners.
HRU
JONHON, Push Pull Type, RJ45MF-CT-07
Working Tools
Cable Cutter
Wire Stripper
Nipper
LAN Tool
The table below outlines the UDA cable pin map:
Table 30.
UDA Cable Pin Map
System Side
Color Map
Description
1
White/Blue
UDA Common RTN
2
Blue
UDA3
3
Orange
UDA2
Shell
Coupling Nut
Push
Pull