Confidential
Chapter 2 Installing System
5G NR HRU Installation Manual v1.0
75
Copyright © 2018, All Rights Reserved.
Figure 78.
Fixing Zero-Bolt Unit Bracket (2)
Fixing Pole Type
This section describes the procedure to fix the HRU on the pole.
Adjustment Chain Bracket Size for 3 Sector
After checking the size of the pole to install the chain bracket, add/remove the
module bracket of the chain bracket according to the size of the pole.
To adjust the chain bracket size, do the following:
Prerequisites
Before proceeding with adjusting the chain bracket size, make sure that you have
the items mentioned in the table below:
1
Zero-Bolt Unit Bracket
M6 Hex. Bolt
(Washer Assembly)
2
Pole Size
Module Bracket Quantity
125 A
4 EA
150 A
5 EA
200 A
6 EA
250 A
8 EA
300 A
9 EA
350 A
10 EA