background image

Installation Instructions CP 5611 A2 
A5E00469482-01 

37 

 

Caution 

without warning triangle indicates that damage to property can 
result if proper precautions are not taken. 

 

 
 

Notice 

indicates that an undesirable result or status can occur if the 
relevant notice is ignored. 

 
 

Note 

highlights important information on the product, using the prod-
uct, or part of the documentation that is of particular importance 
and that will be of benefit to the user. 

 

Trademarks 

SIMATIC

, SIMATIC NET

, SINEC

 and SIMATIC NET Net-

working for Industry® are registered trademarks of Siemens 
AG. 

Third parties using for their own purposes any other names in 
this document which refer to trademarks might infringe upon the 
rights of the trademark owners. 

Safety Instructions Regarding your Product 

Before you use the product described here, read the safety in-
structions below thoroughly. 

Summary of Contents for 6GK1561-1AA01

Page 1: ...05 Installation Instructions Product Information CP 5611 A2 6GK1561 1AA01 Nachfolgend finden Sie Informationen in deutscher Sprache This document contains information in English A5E00469482 01 SIEMENS AG 2005 Änderungen vorbehalten Subject to change A5E00469482 Datasheet Live ...

Page 2: ...Sprachenverzeichnis Language Versions Installationsanleitung deutsch Seite 3 Installation Instructions English Page 35 2 ...

Page 3: ...anleitung Produktinformation Ausgabe 06 2005 CP 5611 A2 6GK1561 1AA01 Nachfolgend finden Sie Informationen in deutscher Sprache A5E00469482 01 SIEMENS AG 2005 Änderungen vorbehalten Siemens Aktiengesellschaft deutsch A5E00469482 ...

Page 4: ...sserungsvorschläge sind wir dankbar Siemens AG Automation and Drives Industrial Communication Postfach 4848 D 90327 Nürnberg A5E00469482 01 Technische Änderungen vorbehalten Siemens Aktiengesellschaft Printed in the Federal Republic of Germany Klassifizierung der Sicherheitshinweise Dieses Dokument enthält Hinweise die Sie zu Ihrer persönli chen Sicherheit sowie zur Vermeidung von Sachschäden beac...

Page 5: ...es oder den jeweiligen Teil der Dokumentation auf den besonders aufmerksam gemacht werden soll und deren Beachtung wegen eines möglichen Nutzens empfohlen wird Marken SIMATIC SIMATIC NET SINEC und SIMATIC NET Net working for Industry sind eingetragene Marken der Siemens AG Die übrigen Bezeichnungen in dieser Schrift können Marken sein deren Benutzung durch Dritte für deren Zwecke die Rech te der I...

Page 6: ...t Das Gerät darf nur für die im Katalog und in der technischen Beschreibung vorgesehenen Einsatzfälle und nur in Verbindung mit von Siemens empfohlenen bzw zugelassenen Fremdgerä ten und komponenten verwendet werden Der einwandfreie und sichere Betrieb des Produktes setzt sachgemäßen Transport sachgemäße Lagerung Aufstellung und Montage sowie sorgfältige Bedienung und Instandhaltung voraus Bevor S...

Page 7: ...mpfohlenen bzw zugelassenen Software Produkten Fremdgeräten und komponenten verwendet wer den Bevor Sie mitgelieferte Beispielprogramme oder selbst erstellte Programme anwenden stellen Sie sicher dass in laufenden Anlagen keine Schäden an Personen oder Maschinen entste hen können Vor der Inbetriebnahme Beachten Sie vor der Inbetriebnahme folgende Warnung Vorsicht Vor der Inbetriebnahme sind die Hi...

Page 8: ...Installationsanleitung CP 5611 A2 8 A5E00469482 01 ...

Page 9: ...au und Anschluss 14 2 2 1 Voraussetzungen und Hinweise 14 2 2 2 Vorgehensweise Einbau CP 5611 A2 15 3 Inbetriebnahme 17 4 Technische Daten 18 5 Umstieg von CP 5611 auf CP 5611 A2 25 6 Weiterführende Informationen 26 7 Zertifikate und Zulassungen 29 7 1 Hinweise zur CE Kennzeichnung von SIMATIC NET Produkten 29 7 2 Hinweis für Australien 31 7 3 Hinweis für Kanada 32 7 4 Hinweise für USA 33 ...

Page 10: ...ittstel lensignale für die PLC Direktkopplung PLC Programmable Logic Control werden bis 187 5 kbit s un terstützt Zweck der Installationsanleitung Produktinformation Diese Installationsbeschreibung Produktinformation unter stützt Sie den Kommunikationsprozessor CP 5611 A2 in Ihrem PG PC einzubauen und informiert Sie über die Ei genschaften des Produkts Gültigkeitsbereich dieser Installationsanleit...

Page 11: ...eräte PC PG SIMATIC S7 oder ET 200 zu einem Netzsegment gekoppelt werden Durch Kopplung mehrerer Segmente mit Repeatern sind maximal 127 Teil nehmer anschließbar Die physikalische Kopplung der MPI DP Schnittstelle an das MPI DP Netz erfolgt über ein potentialgetrenntes RS485 Interface das Bestandteil der Baugruppe ist Im MPI DP Netz sind je nach Netzkonfiguration Datenübertra gungsraten von 9 6 kb...

Page 12: ...ln EGB Richtlinien Warnung Fassen Sie Bauelemente und Baugruppen nur am Rand an Anschlussstifte und Leiterbahnen dürfen Sie nicht be rühren Bevor Sie das Gerät öffnen müssen Sie die elektrosta tische Ladung von Ihrem Körper ableiten Das kann dadurch geschehen dass Sie Metallteile an der Rück wand des Geräts berühren bevor Sie das Stromversorgungskabel ziehen Auch von Werkzeugen die Sie für die Arb...

Page 13: ...inbau des CP 5611 A2 Das Öffnen des PG PC sowie das Stecken und Ziehen der Baugruppe ist nur im spannungslosen Zustand erlaubt Handbuch lesen Bitte lesen Sie vor Einbau der Baugruppe im Handbuch Ihres PG PC das Kapitel Einbau von Baugruppen o ä ganz durch und beachten Sie die Anweisungen ...

Page 14: ... und 5V Steckplätze unterstützt Eben falls unterstützt werden PCI X Steckplätze mit 32 oder 64 Bit Die Baugruppe hat die Abmessungen einer kurzen PCI Baugruppe 102 mm x 130 mm Hinweis Für den DP Betrieb wird eine Mindestausstattung mit ei nem Pentiumprozessor mit 166 MHz oder mit einem vergleichbaren Prozessor empfohlen Software Voraussetzungen Die Software zum Betrieb der Baugruppe gehört nicht z...

Page 15: ... Sie die Regeln für die Hantierung von elektrosta tisch gefährdeten Bauelementen EGB Richtlinie Achtung 2 Wenn Sie den CP 5611 A2 in einen vorgesehenen PCI Slot stecken und ordnungsgemäß das Blech am Ge häuse befestigen dann kann es bei Rechnern verschiedener Hersteller vorkommen dass die Baugruppe im PCI Slot in eine Schieflage gerät Bitte stellen Sie nach dem Befestigen der Baugruppe nochmals de...

Page 16: ... wie im Hand buch Ihres PG PC beschrieben 3 Stecken Sie den CP 5611 A2 in einen PCI Steckplatz Achten Sie darauf dass der CP 5611 A2 fest und gleichmäßig in der Aufnahmebuchse des Steckplatzes steckt Achtung Greifen Sie dabei beim Hantieren der Baugrup pe nicht auf die Anschlüsse bzw auf die elektronischen Bauelemente 4 Schließen Sie das Rechnergehäuse wie im Handbuch Ihres PG PC beschrieben 5 Ste...

Page 17: ...f könnten folgende Ursachen vorliegen Ursache Abhilfe Die von der Baugruppe an geforderten Ressourcen stehen nicht zur Verfügung Dies wird vom PCI BIOS noch vor dem Booten auf dem Bildschirm ausgege ben Die Meldung ist BIOS ab hängig und kann wie folgt aussehen Resource Con flict PCI Network Controller in slot Ändern Sie den Hardware Ausbau des Rechners so dass die angeforderten Ressourcen zur Ver...

Page 18: ...CP 5611 A2 Konstruktiver Aufbau Baugruppenformat Flachbaugruppe kurzes PCI Format Maße H x T in mm 102 x 130 Gewicht ca 100 g Baugruppen Steckprinzip PCI Bus Direktstecker 32 bit Bus Interface PCI V2 2 Plug and Play Spannung Betriebsspannung Sicherheitsspannung SELV nach EN 60950 Nennspannung Grenzwerte 5 VDC 4 75 bis 5 25 V Stromaufnahme Stromaufnahme bei Nenn spannung Max 500 mA ...

Page 19: ...atz 3 3 V 5 V 32 bit 33 66 MHz Bustakt Steckverbinder 9 polige D SUB Buchsen leiste mit Schraubver riegelung Übertragungsart RS 485 erdfrei innerhalb der SELV Grenzen Betriebsart der MPI DP Schnittstelle Potentialfrei Schnittstellen signale erdgebunden Leitungsschirm Datenübertragung Übertragungs geschwindigkeit 9 6 kbit s bis 12 Mbit s ...

Page 20: ...glichkeit EMV Störaussendung Klasse B nach EN 55022 FCC Klasse B Störfestigkeit auf Signallei tungen 2 kV nach IEC 61000 4 5 Surge 1 kV nach IEC 61000 4 3 Burst Störfestigkeit gegen Entla den statischer Elektrizität 6 kV Contact discharge nach IEC 61000 4 2 Störfestigkeit gegen Hoch frequenzeinstrahlung 10 V m bei 80 MHz 2 GHz nach IEC 61000 4 3 10 V m mit 80 Amplitu denmodulation mit 1 kHz 10 kHz...

Page 21: ... temperatur 20 C bis 60 C Temperaturänderung max 20 K h Feuchte Betrieb Geprüft nach EN IEC 60068 2 78 5 bis 85 bei 30 C keine Betauung Rascher Temperaturwech sel im Betrieb 5 C bis 55 C nach IEC 60068 2 14 5 Zyklen Rascher Temperaturwech sel bei Lagerung Transport 20 C bis 60 C nach IEC 60068 2 14 2 Zyklen Temperaturwechsel bei Feuchte bei Lage rung Transport Geprüft nach EN IEC 60068 2 30 25 C b...

Page 22: ...2 A5E00469482 01 Mechanische Umgebungsbedingungen Betriebsschwingung Geprüft nach IEC 60068 2 6 10 bis 58 Hz Amplitude 0 075 mm 58 bis 500 Hz Beschleunigung 10 m s2 10 Zyklen Achse Betriebsschocken Geprüft nach IEC 60068 2 27 Halbsinus 50 m s2 5 g 30 ms 100 Schocks Achse ...

Page 23: ...be schaltet Bei anderen MPI DP Komponenten kann auf diesem Pin der Rücklei ter der potentialfreien 24 V Versorgung liegen 3 LTG_B Signalleitung B der CP 5611 A2 Baugruppe Ein Ausgang 4 RTSAS RTSAS Eingangssignal für MPI DP Bus Das Steuer signal ist 1 aktiv wenn die AS sendet Eingang 5 M5EXT M5EXT Rückleiter GND der 5 V Versorgung Die Strombelastung durch ei nen externen Verbraucher der zwischen P5...

Page 24: ...T angeschlossen wird darf max 90 mA betragen kurzschlussfest 7 NC P24V Buchse Pin 7 ist nicht be schaltet Bei anderen MPI DP Komponenten kann auf diesem Pin die Versor gung P24V der potentialfreien 24 V Versorgung liegen 8 LTG_A Signalleitung A der CP 5611 A2 Baugruppe Ein Ausgang 9 RTS RTS Ausgangssignal der CP 5611 A2 Baugruppe Das Steuersignal ist 1 aktiv wenn das Gerät PG oder PC sendet Ausgan...

Page 25: ...erung notwendig Gehen Sie wie folgt beschrieben vor Schritt Vorgehen 1 Schalten Sie den PC aus 2 Bauen Sie den CP 5611 aus 3 Bauen Sie den CP 5611 A2 in denselben PCI Slot ein 4 Starten Sie den PC erneut Hinweis Wenn der Hardware Assistent von Windows erscheint dann bestätigen Sie die vorgeschla gene Schritte Vorsicht Beachten Sie die vorstehenden Warn und Sicherheitshin weise Hinweis Die bisher v...

Page 26: ...IC NET Produktkatalog IK PI verfügbar auf der SIMATIC NET Dokumentations CD un ter Katalog IK PI Industrielle Kommunikation und Feldge räte Doppelklick auf Datei START HTM im Hauptverzeichnis der SIMATIC NET Dokumentations CD Deutsch Auswahlfeld unterhalb Industrial Communication SIMATIC NET Kataloge Katalog IK PI Industrielle Kommunikation und Feldgeräte Weltweit Nürnberg Technical Support Ortsze...

Page 27: ...ww siemens de automation support request GMT 1 00 United States Johnson City Technical Support and Authorization Ortszeit Mo Fr 8 00 bis 17 00 Telefon 1 423 262 2522 Fax 1 423 262 2289 E Mail simatic hotline sea siemens com GMT 5 00 Asien Australien Peking Technical Support and Authorization Ortszeit Mo Fr 8 00 bis 17 00 Telefon 86 10 64 71 99 90 Fax 86 10 64 74 74 74 E Mail adsupport asia siemens...

Page 28: ...r der Sie ständig mit den aktuellsten In formationen zu Ihren Produkten versorgt die für Sie richtigen Dokumente über unsere Suche in Service Support ein Forum in welchem Anwender und Spezialisten welt weit Erfahrungen austauschen Informationen über Vor Ort Service Reparaturen Er satzteile Vieles mehr steht für Sie unter dem Begriff Leistungen bereit Ihren Ansprechpartner für Automation Drives vor...

Page 29: ... EMV Richtlinie Die obigen SIMATIC NET Produkte erfüllen die Anforde rungen folgender EG Richtlinie Richtlinie 89 336 EWG Elektromagnetische Verträglich keit Einsatzbereich Die Produkte sind ausgelegt für den Einsatz in folgenden Bereichen Einsatzbereich Anforderungen an Störaus sendung Störfestigkeit Wohnbereich Geschäfts und Gewerbebereich sowie Kleinbetriebe EN 61000 6 3 EN 61000 6 2 Industrieb...

Page 30: ... vor dem Berüh ren der Baugruppe elektrostatisch entladen Hinweis Das Produkt wurde in einem Gerät getestet das ebenfalls die oben genannten Normen einhält Beim Betrieb der Baugruppe in einem Gerät das diese Normen nicht erfüllt kann die Einhaltung der entsprechen den Werte nicht garantiert werden Ablagehinweis Bitte legen Sie diese Informationen zum CE Zeichen in Ih rem PROFIBUS Netzhandbuch ab K...

Page 31: ...nie 89 392 EWG Nach der Maschinenrichtlinie sind wir verpflichtet darauf hinzuweisen dass das bezeichnete Produkt ausschließlich zum Einbau in eine Maschine bestimmt ist Bevor das Endprodukt in Betrieb genommen wird muss sichergestellt sein dass es mit der Richtlinie 89 392 EWG konform ist 7 2 Hinweis für Australien Das Produkt CP 5611 A2 erfüllt die Anforderungen der Norm AS NZS 3548 ...

Page 32: ...2 A5E00469482 01 7 3 Hinweis für Kanada ICES Konformität Das digitale Klasse B Produkt CP 5611 A2 erfüllt die An forderungen der kanadischen Norm ICES 003 CSA Zulassung Das SIMATIC NET Produkt CP 5611 A2 verfügt über eine Zulassung nach Standard CAN CSA C 22 2 No 60950 1 ...

Page 33: ...ence will not occur in a particular installation If this equipment does cause harmful interfer ence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or mo re of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and re ceiver Conn...

Page 34: ...nstallationsanleitung CP 5611 A2 Installationsanleitung CP 5611 A2 34 A5E00469482 01 UL Zulassung Das SIMATIC NET Produkt CP 5611 A2 verfügt über eine Zulassung UL nach Standard UL 60950 1 First Edition ...

Page 35: ...allation Instructions Product Information Release 06 2005 CP 5611 A2 6GK1561 1AA01 Below you will find information in English A5E00469482 01 SIEMENS AG 2005 Subject to change Siemens Aktiengesellschaft English A5E00469482 ...

Page 36: ... are welcomed Siemens AG Automation and Drives Industrial Communication Postfach 4848 D 90327 Nürnberg A5E00469482 01 Subject to technical change Siemens Aktiengesellschaft Printed in the Federal Republic of Germany Classification of Safety Related Notices This document contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equi...

Page 37: ...ng the prod uct or part of the documentation that is of particular importance and that will be of benefit to the user Trademarks SIMATIC SIMATIC NET SINEC and SIMATIC NET Net working for Industry are registered trademarks of Siemens AG Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners Safety ...

Page 38: ...used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens This prod uct can only function correctly and safely if it is transported stored set up and installed correctly and operated and main tained as recommended Before you use the supplied sample pro...

Page 39: ...oftware products from other manufacturers which have been approved or recommended by Siemens Before you use the supplied sample programs or programs you have written yourself make certain that no injury to persons nor damage to equipment can result in your plant or process Prior to Startup Before putting the product into operation note the following warning Caution Before installing and starting t...

Page 40: ...Installation Instructions CP 5611 A2 40 A5E00469482 01 ...

Page 41: ...otes 44 2 2 Installing and Connecting 46 2 2 1 Requirements and Notes 46 2 2 2 How to Install the CP 5611 A2 47 3 Commissioning 49 4 Technical Specifications 50 5 Changing from CP 5611 to CP 5611 A2 57 6 Further Information 58 7 Certificates and Approvals 61 7 1 Notes on the CE Mark of SIMATIC NET Products 61 7 2 Note for Australia 63 7 3 Note for Canada 64 7 4 Notes for USA 65 ...

Page 42: ...rface signals for the PLC direct link PLC Programmable Logic Controller are supported up to 187 5 Kbps Purpose of the Installation Instructions Product Infor mation Bulletin This installation description product information bulletin supports you when installing the CP 5611 A2 communica tions processor in your PG PC and informs you of the properties of the product Validity of these Installation Ins...

Page 43: ...32 devices PC PG SIMATIC S7 or ET 200 can be con nected together to form a network segment By coupling several segments with repeaters a maximum of 127 nodes can be connected The physical coupling of the MPI DP interface to the MPI DP network is over a floating RS 485 interface that is part of the module Depending on the network configuration in the MPI DP network data transmission rates of 9 6 Kb...

Page 44: ...eep to the follow ing rules ESD guidelines Warning Pick up components and modules only by their edges Do not touch the pins or conductors Before opening the device make sure that you dis charge any electrostatic charge from your body You can do this by touching metal parts on the back panel of the device before unplugging the power supply cable Make sure that you also discharge any electrostatic c...

Page 45: ... 45 Installing the CP 5611 A2 Opening the PG PC and inserting or removing the module is permitted only when the power is turned off Read the Manual Before installing the module please read the section on installing modules thoroughly in the manual of your PG PC and follow the instructions ...

Page 46: ...ding to the PCI standard in other words 3 3 and 5 V slots are supported PCI X slots with 32 or 64 bits are also supported The module has the dimensions of a short PCI module 102 mm x 130 mm Note For the DP mode at least a 166 MHz Pentium processor or comparable processor is recommended Software Requirements The software for operating the module is not supplied with the module You can order this fr...

Page 47: ...tatic discharge Please keep to the rules for handling components sensitive to electrostatic discharge ESD guidelines Caution 2 If you insert the CP 5611 A2 in a suitable PCI slot and then secure the metal panel to the housing the module some times skews in the slot in computers of some manufacturers After securing the module please make sure that it is still sitting correctly and firmly in the slo...

Page 48: ...nector from the socket 2 Open the computer housing as described in the manual for your PG PC 3 Insert the CP 5611 A2 in a PCI slot Make sure that the CP 5611 A2 sits firmly and uniformly in the slot Notice When handling the module do not touch the terminals or the electronic components 4 Close the computer housing as described in the manual for your PG PC 5 Reinsert the power supply connector in t...

Page 49: ...ion this may be due to the following problems Cause Remedy The resources required by the module are not avail able This is displayed by the PCI BIOS on the screen prior to booting The message depends on the particular BIOS but will say something like Re source Conflict PCI Network Controller in slot Change the hardware con figuration of the computer so that the required re sources are available se...

Page 50: ...processor Construction Module format PC card short PCI format Dimensions H x D in mm 102 x 130 Weight Approx 100 g Module insertion principle PCI bus direct connect 32 bits Bus interface PCI V2 2 plug and play Voltage Operating voltage Safety extra low voltage SELV complying with EN 60950 Rated voltage limit values 5 VDC 4 75 to 5 25 V Current consumption Current consumption at rated voltage 500 m...

Page 51: ...I X slot 3 3 V 5 V 32 bits 33 66 MHz bus clock rate Plug in connectors 9 pin D sub female connec tors with screw securing mechanism Type of transmission RS 485 floating within the SELV limits Mode of the MPI DP inter face Floating interface signals non floating cable shield Data Transmission Transmission rate 9 6 Kbps to 12 Mbps ...

Page 52: ...p proval Electromagnetic Compatibility EMC Noise emission Class B to EN 55022 FCC class B Noise immunity on signal lines 2 kV to IEC 61000 4 5 surge 1 kV to IEC 61000 4 3 burst Immunity to electrostatic discharge 6 kV contact discharge to IEC 61000 4 2 Immunity to high frequency interference 10 V m at 80 MHz 2 GHz to IEC 61000 4 3 10 V m with 80 ampli tude modulation with 1 kHz 10 kHz 80 MHz to IE...

Page 53: ...em perature 20 C to 60 C Temperature change max 20 K h Humidity operation Tested to EN IEC 60068 2 78 5 to 85 at 30 C no condensation Fast temperature change during operation 5 C to 55 C to IEC 60068 2 14 5 cycles Fast temperature change during storage transporta tion 20 C to 60 C to IEC 60068 2 14 2 cycles Temperature change with humidity during storage transportation Tested to EN IEC 60068 2 30 ...

Page 54: ...P 5611 A2 54 A5E00469482 01 Mechanical Environmental Conditions Vibration Tested to IEC 60068 2 6 10 to 58 Hz Amplitude 0 075 mm 58 to 500 Hz Acceleration 10 m s2 10 cycles axis Shock in operation Tested to IEC 60068 2 27 Half sine 50 m s2 5 g 30 ms 100 shocks axis ...

Page 55: ...cket pin 2 is not used With other MPI DP compo nents the return wire of the floating 24 V power supply can be applied to this pin 3 LTG_B Signal line B of the CP 5611 A2 module Input output 4 RTSAS RTSAS input signal for MPI DP bus The control signal is 1 active when the PLC is sending Input 5 M5EXT M5EXT return wire GND of the 5 V power supply The current load of an ex ternal consumer connected b...

Page 56: ... and M5EXT can be up to a maximum of 90 mA short circuit proof 7 NC P24V Socket pin 7 is not used With other MPI DP compo nents the P24V pin of the 24 V floating power supply can be applied to this pin 8 LTG_A Signal line A of the CP 5611 A2 module Input output 9 RTS RTS output signal of the CP 5611 A2 module The control signal is 1 active when the device PG or PC is sending Output Shield On conne...

Page 57: ...equires neither software updates nor a change to the configuration Follow the steps below Step Procedure 1 Turn the PC off 2 Remove the CP 5611 3 Insert the CP 5611 A2 in the same PCI slot 4 Restart the PC Note When the Windows hardware wizard appears confirm the proposed steps Caution Observe the warnings and safety related notices Note The previously used configuration is loaded automatically ...

Page 58: ...atalog IK PI available on the SIMATIC NET Documentation CD under IK PI Catalog Industrial Communication and Field De vices double click on the START HTM file in the main direc tory of the SIMATIC NET Documentation CD English list box below Industrial Communication SIMATIC NET Catalogs IK PI Catalog Industrial Commu nication and Field Devices Worldwide Nuernberg Technical Support Local time 24 hour...

Page 59: ...w siemens de automation support request GMT 1 00 United States Johnson City Technical Support and Authorization Local time Mo Fr 8 00 a m to 5 00 p m Telephone 1 423 262 2522 Fax 1 423 262 2289 E mail simatic hotline sea siemens com GMT 5 00 Asia Australia Peking Technical Support and Au thorization Local time Mo Fr 8 00 a m to 5 00 p m Telephone 86 10 64 71 99 90 Fax 86 10 64 74 74 74 E mail adsu...

Page 60: ...nd the following information Newsletter providing the latest information on your prod ucts Exactly the right documents for your needs which you can access by performing an online search in Service Support Forum in which users and experts worldwide exchange ideas Information about local service repair and replacement parts Much more information can be found under Ser vices You will find your local ...

Page 61: ...GK1561 1AA01 EMC Directive The SIMATIC NET products listed above meet the re quirements of the following EU directive 89 336 EEC Electromagnetic Compatibility Field of Application The products are designed for use in the following areas Field of Application Requirements Noise Emis sion Immunity to Interference Household commercial light industry EN 61000 6 3 EN 61000 6 2 Industry EN 61000 6 3 EN 6...

Page 62: ...ching the module Note The product was tested in a device that also conforms to the standards listed above When operating the module in a device that does not con form to these standards there can be no guarantee that the values will be adhered to Filing the Information Please file this information on the CE mark in your PROFIBUS Network Manual Conformity Certificates The EU declaration of conformi...

Page 63: ...tive on machines 89 392 EEC According to the directive on machines we are obliged to point out that the product described is intended solely for installation in a machine Before the final product can be put into operation it must be tested to ensure that it con forms with the directive 89 392 EEC 7 2 Note for Australia The product CP 5611 A2 meets the requirements of the AS NZS 3548 standard ...

Page 64: ...ada ICES Conformity Canadian Notice This Class B digital apparatus complies with Canadian ICES 003 Avis Canadien Ces appareils numérique de la classe B est conforme à la norme NMB 003 du Canada CSA Approval The SIMATIC NET Product CP 5611 A2 has an approval according to the standard CAN CSA C 22 2 No 60950 1 ...

Page 65: ...erence will not occur in a particular installation If this equipment does cause harmful interfer ence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and re ceiver Con...

Page 66: ...tallation Instructions CP 5611 A2 Installation Instructions CP 5611 A2 66 A5E00469482 01 UL approval The SIMATIC NET product CP 5611 A2 has an approval UL according to the standard UL 60950 1 First Edition ...

Reviews: