Troubleshooting
60
Samsung Electronics
IPM(IGBT module) over current error (E464) (cont.)
Yes
No
Are the position and measured
value of temperature sensor normal?
reposition the sensor
reposition the sensor
cont.
Is the value of resistance
mega
Ω
between compressor
and outdoor unit body?
Yes
No
Exchange the compressor
Exchange INVERTER PCB