![background image](http://html.mh-extra.com/html/samsung/ag042ksvanh/ag042ksvanh_service-manual_340757022.webp)
18
3-3-2. Temperature sensor & Pressure sensor in the water pipe side
- Exchange method of the water temperature sensor
1) Power off before starting on work.
2) Unscrews the fixed screw of CABINET FRONT and C-BOX.
3) Separate the connector from PBA
4) Separate Insu protecting the temperature sensor.
5) Separate the temperature sensor by using spanner.
6) Separate the temperature sensor.
It is applied Thermal Grease for an accurate temperature
measurement.
Ŷ
Cover the temperature sensor with Insu so that it is not affected from
the outside.
- Bolt torque : 120±10% kgfcm