4-5-5 IPM Over Current error
1. Check items
1) Is the coolant changed?
2) Is the compressor running normally?
3) Is the compressor connected correctly?
4) Are there any obstacles near the indoor and outdoor units?
2. Check procedure
U-V
V-W
W-U
AJ020JCJ2CH
0.5~1.1Ω
0.5~1.1Ω
0.5~1.1Ω
AJ024JCJ3CH
0.2~0.6Ω
0.2~0.6Ω
0.2~0.6Ω
AJ036JCJ5CH
0.1~0.5Ω
0.1~0.5Ω
0.1~0.5Ω
Checking Comp Resistance ( Normal value )