E-
20
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges,
within which the air conditioner can be used.
If the air conditioner is used at...
Then...
The automatic protection feature may be
triggered and the air conditioner stopped.
High temperature
A water leakage or some other
malfunction may happen if the heat
exchanger freezes.
Low temperature
Water may condense on and drip from
the surface of the indoor unit if it is used
for a long periods.
High humidity levels
Mode
Outdoor Temperature
Indoor Temperature
Indoor Humidity
Heating
Cooling
Drying
0°C to 24°C approx.
21°C to 54°C approx.
18°C to 54°C approx.
27°C or less.
18°C to 32°C approx.
18°C to 32°C approx.
-
80% or less
-
❇
If the outdoor temperature is as low as 0°C, the heating capacity drops
up to 70~80%depending on the operation condition.
If the cooling operation is used at over 33°C(indoor temperature),
it does not cool at its full capacity.