40
English
Ins
tallation
WARNING
•
In case of extending the
electric wire, please DO
NOT use a round-shaped
pressing socket.
– Incomplete wire
connections can cause electric shock or a fire.
Step 2.5 Installing and connecting the
drain hose
1
Install the drain hose.
Drain hose
Assembly pipe
Connection hose
Wall
5 cm
less
Ditch
Water
Slant downwards
Slant upwards
Dipped in water
Bent
Too small
clearance
Too small
clearance
Indoor unit
Drain hose
2
Pour water into the drain pan. Check whether the
hose is well drained.
CAUTION
•
Make sure that the indoor unit is in upright position
when you pour water to check for leakage. Make sure
that the water does not overflow onto the electrical
part.
•
If the diameter of the connection hose is smaller than
the product's drain hose, water leakage may occur.
•
Inadequate installation may cause water leakage.
•
If the drain hose is routed inside the room, insulate
the hose so that dripping condensation does not
damage the furniture or floors.
•
Do not box in or cover the drain hose connection.
Drain hose connection must be easily accessible and
serviceable.
Step 2.6 Optional: Extending the
drain hose
(A)
(B)
Drain hose (A)
Extension drain hose (B)
Drain hose
Extension drain hose
20 mm or more
Foam insulation
Vinyl tape
DB68-06039A-00.indd 40