Alignment and Adjustments
Samsung Electronics
3-2
3-1-1 Room temperature sensor Error
No
ASS'Y Sensor Replace
SENSOR Resistance Value : 20˚C-12.09k
Ω
SENSOR Resistance Value :
30˚C-8.31k
Ω
SENSOR Resistance Value :
35˚C-6.94k
Ω
SENSOR Resistance Value :
40˚C-5.83k
Ω
Yes
No
No
Detach the assembly sensor from the
ASS'Y PCB CN43 connector and measure
the sensor resistance with an ohmmeter (tester)
between Pin #1 and #2.
Connect the sensor to CN43,
supply power, and measure the voltage of
#1 and #2 of the CN43 connector.
MICOM Error or Connector(CN43) check
Is the sensor resistance value
10K
Ω
±3% at the room temperature
of 25˚C?
Yes
Poor ASS'Y PCB Replace
Below 0.5V?
Yes
Poor ASS'Y PCB Replace
Over 4.9V?
Error Mode
LAMP
7-segment Display
Indoor unit room temperature sensor error(open or short)
24610A(1)_1 11/10/05 6:26 PM Page 3-2
Summary of Contents for AS12HPCN
Page 28: ...MEMO 4 8 Samsung Electronics...
Page 34: ...MEMO 5 6 Samsung Electronics...