12-2
Samsung Electronics
1. Checklist :
1) Is input voltage normal?
2) Is AC power linked correctly?
3) Is input voltage of DC regulator IC KA7805 (IC02) normal? (11VDC-12.5VDC)
4) Is output voltage of DC regulator IC KA7805 (IC02) normal? (4.5VDC-5.5VDC)
2. Troubleshooting procedure
Unplug the power cord and
plug it after 5 seconds
Press the Power Button on the
remote control unit to
operate the air conditioner
Check whether 2 wires
of power cord are
connected correctly to the
terminal block and control board.
Check whether the fuse on the
control board is normal.
FUSE(F701): T2.5[A]/250[V]
Check the output of SMPS
on the control board.
Input power: AC230±15%[V]
IC02 Input: DC12[V]
IC02 output: DC5[V]
◆
Check the setting temperature
◆
Check the indoor unit
control board
◆
Check the display board
Reconnect wires correctly
Replace fuse
PCB should be replaced
operate
does not operate
Yes
Yes
Yes
No
No
No
12-2 Fault Diagnosis by Symptom
12-2-1 No Power (completely dead)-Initial diagnosis
24610A(1)_1 11/10/05 6:26 PM Page 10-7
Summary of Contents for AS12HPCN
Page 28: ...MEMO 4 8 Samsung Electronics...
Page 34: ...MEMO 5 6 Samsung Electronics...
Page 76: ...MEMO Samsung Electronics 14 11...