background image

E-

2

Safety Precautions

The following safety precautions must be taken when using your air conditioner.

Users of this product are cautioned not to attempt repair of this product
at their own discretion. Instead, they are requested to directly contact a
designated service center or the outlet at which the product was 
purchased.

Never spill any kind of liquid into the unit. Should this happen, unplug 
or main switch off the unit and contact an authorized service center.

Do not insert anything between the air outlet blades because the inner 
fan may be damaged and could cause injury. Keep children away from
the unit.

Do not place any obstacles in front of the unit.

Do not spray liquid of any kind into the indoor unit. Should this happen,
switch off the breaker used for your air conditioner and contact your
installation specialist.

Make sure that the unit is correctly ventilated at all times: 
Do not place clothing or other materials over it.

If the wireless remote control will not be used for a long time, remove
the batteries. (If applicable)

When using a wireless remote control, the distance should not be more
than 7 meters from the air conditioner. (If applicable)

WARNING

D

URING OPERATION

Never store or ship the air conditioner upside down or sideways to
avoid damage to the compressor.

The appliance is not intended for use by young children or infirm 
persons without supervision: Young children should be supervised to
ensure that they do not play with the appliance.

Max current is measured according to IEC standard for safety and 
current is measured according to ISO standard for energy efficiency.

O

THERS

Before throwing out the device, it is necessary to pull back the battery
cells and get rid of them safely for recycling reasons.

When you need to dispose of the unit, consult your dealer. If pipes are
removed incorrectly, refrigerant may blow out and come into contact
with your skin, causing injury. Releasing refrigerant into the atmosphere
also damages the environments.

Please recycle or dispose of the packaging material for this product in
an environmentally responsible manner.

D

ISPOSING OF THE UNIT

Risk of electric shock. 

• 

Can cause injury or death. 

• 

Disconnect all

remote electric power supplies before servicing, installing or cleaning. 

• 

This must be done by the manufacturer or its service agent or a similar

qualified person in order to avoid a hazard.

Summary of Contents for AST12P4GB/UMG

Page 1: ...o dom stico sistema Split Refrigeraci n Climatiseur de type S par Refroidissement AST12P4GB AST12P4GE AST18P0GBA AST18P0GEA AST24P6GBA AST24P6GEA Indoor unit UST12P4GB UST12P4GE UST18P0GBA UST18P0GEA...

Page 2: ...distance should not be more than 7 meters from the air conditioner If applicable WARNING DURING OPERATION Never store or ship the air conditioner upside down or sideways to avoid damage to the compres...

Page 3: ...Your Room 13 Selecting Energy Saving Mode 14 Generating Anion 15 Adjusting the Air Flow Direction Vertically 16 Adjusting the Air Flow Direction Horizontally 17 PROGRAMMING YOUR AIR CONDITIONER Setti...

Page 4: ...the temperature on the display N N N No o o ot t t te e e e Indoor Unit Air filter under the grille Air flow blades outlet Remote Control Sensor On Off switch Timer indicator Fan speed setting Sleep T...

Page 5: ...E 5 ENGLISH Air Inlet Rear Air Outlet Connection Valve Outdoor Unit UST12P4GB UST12P4GE Air Inlet Rear Air Outlet Connection Valve Outdoor Unit UST18P0GBA UST18P0GEA UST24P6GBA UST24P6GEA...

Page 6: ...n button Sleep button Energy saving button Swing button Timer Set Cancel button Temperature adjustment buttons Temperature setting Air flow direction Turbo mode Sleep mode On Off button Mode selection...

Page 7: ...ake full advantage of the unit s features The booklet is organized as follows The following figures are shown on pages from 4 to 6 Indoor and outdoor units Remote control buttons and display They will...

Page 8: ...battery with on the remote control 1 2 Close the cover by sliding it back until it clicks into place 3 Use two AAA LR03 1 5V batteries Do not use old batteries or different kinds of batteries togethe...

Page 9: ...lt The indoor unit beeps each time you press the button The air conditioner runs in AUTO mode 2 You can change modes at any time If necessary press the On Off button Result The air conditioner starts...

Page 10: ...ssible temperatures are between 18 C and 30 C inclusive Result Each time you press the button The temperature is adjusted by 1 C The indoor unit beeps The air conditioner starts cooling provided that...

Page 11: ...automatically to the mode and temperature previously selected 1 If necessary press the On Off button 2 Press the button Result The temperature and fan settings are adjusted automatically The air cond...

Page 12: ...ult The indoor unit beeps each time you press the button The air conditioner runs in DRY mode N N N No o o ot t t te e e e You can change modes at any time 3 To adjust the temperature press the button...

Page 13: ...button The air conditioner runs in FAN mode The temperature is set automatically N N N No o o ot t t te e e e You can change modes at any time 3 Select the fan speed by pressing the button one or mor...

Page 14: ...er 26 C cancel the Energy saving mode before adjusting the temperature 6 To control the direction of the air flow refer to pages 16 and 17 5 To select the fan speed press the button one or more times...

Page 15: ...onditioner generates anion The indoor unit beeps 2 If you wish to stop the Anion function press the button again Result The air conditioner is reset automatically to the previous mode temperature and...

Page 16: ...uired Result The outer blade is adjusted vertically RECOMMENDATION When Adjust the blade to face Cooling Upwards 2 If you want the blade to move up and down automatically when the air conditioner is o...

Page 17: ...are two sets of inner air flow blades Just as the outer air flow blade can be adjusted vertically the inner blades can be adjusted horizontally 1 Adjust each set of inner blades to the required positi...

Page 18: ...nclusive 1 Press the Set Cancel button to complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The selected mode and the temperature on the display disappe...

Page 19: ...o complete the setting Result The remaining time is displayed Blinking of the timer indicator stops The air conditioner will switch off automatically when the counter displayed on the remote control r...

Page 20: ...s the button Result The indoor unit beeps The air conditioner will be controlled as indicated in the illustrations below Cooling The desired temperature is increased by 1 C every hour When it has been...

Page 21: ...u should follow when using your air conditioner Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating the unit is switched off When the power returns the a...

Page 22: ...ty levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods E 22 Operating Your Air Conditioner Without the Remote Control Your air conditioner can be o...

Page 23: ...ay be too low Dust may be blocking the air filter guard refer to page 24 for cleaning instructions Check that there is no obstacle in front of the outdoor unit Check that the operating mode is set to...

Page 24: ...t side of grille support then insert the right side of grille support IMPORTANT Hook Body groove Grille support Lower front grille N N N No o o ot t t te e e e If you have not used the air conditioner...

Page 25: ...E 25 ENGLISH Technical Specifications Model Indoor unit 220V 60Hz AST12P4GE AST18P0GEA AST24P6GEA AST12P4GB AST18P0GBA AST24P6GBA 220 240V 50Hz Power Supply...

Page 26: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR Printed in Korea...

Reviews: