3-2 Function Description
3-2-1 Cooling operation mode
3-2
Samsung Electronics
FAN
COOL
POWER / MODE
°
C
Hour
Remote control sensor
Temperature/Timer settings
Temperature indicator
Timer indicator
POWER/MODE BUTTON
Operating mode indicator
The compressor is turned on and off according to the ambient temperature and set temperature.
1. Compressor on and off control
• Compressor on and off control according to the ambient temperature.
*
The compressor is turned off when "ambient temperature = set temperature -1˚C"
*
The compressor is turned on when "ambient temperature = set tempe1˚C"
2. Default value after power reset
➔
set temperature = 18˚C
FAN SPEED = HIGH
3. Set temperature indicating (setting) range : 1˚C interval from 18˚C to 30˚C.
3-2-2 Fan operation mode
1. If "Fan operation mode" signal is received from remocon.
➔
the compressor is immediately turned off and only fan motor is operated at set blowing speed.
➔
it changes such as "HIGH
➔
LOW
➔
HIGH"( if Fan speed is selected).
2. The initial FAN speed is set to "HIGH".
3. The set temperature can not be indicated and set.
AW126JB-1 6/27/98 10:38 AM Page 6