SAM47 INSTRUCTION SET
KS57C2308/P2308/C2316/P2316
5-74
RCF
— Reset Carry Flag
RCF
Operation:
Operand
Operation Summary
Bytes
Cycles
–
Reset carry flag to logic zero
1
1
Description:
The carry flag is cleared to logic zero, regardless of its previous value.
Operand
Binary Code
Operation Notation
–
1
1
1
0
0
1
1
0
C
←
0
Example:
Assuming the carry flag is set to logic one, the instruction
RCF
resets (clears) the carry flag to logic zero.