KS57C2308/P2308/C2316/P2316
ADDRESSING MODES
3-1
3
ADDRESSING MODES
OVERVIEW
The enable memory bank flag, EMB, controls the two addressing modes for data memory. When the EMB flag is
set to logic one, you can address the entire RAM area; when the EMB flag is cleared to logic zero, the
addressable area in the RAM is restricted to specific locations.
The EMB flag works in connection with the select memory bank instruction, SMB n. You will recall that the SMB
n instruction is used to select RAM bank 0, 1 or 15. The SMB setting is always contained in the upper four bits of
a 12-bit RAM address. For this reason, both addressing modes (EMB = "0" and EMB = "1") apply specifically to
the memory bank indicated by the SMB instruction, and any restrictions to the addressable area within banks 0, 1
or 15. Direct and indirect 1-bit, 4-bit, and 8-bit addressing methods can be used. Several RAM locations are
addressable at all times, regardless of the current EMB flag setting.
Here are a few guidelines to keep in mind regarding data memory addressing:
— When you address peripheral hardware locations in bank 15, the mnemonic for the memory-mapped
hardware component can be used as the operand in place of the actual address location.
— Always use an even-numbered RAM address as the operand in 8-bit direct and indirect addressing.
— With direct addressing, use the RAM address as the instruction operand; with indirect addressing, the
instruction specifies a register which contains the operand's address.
Summary of Contents for C2316
Page 30: ...ADDRESS SPACES KS57C2308 P2308 C2316 P2316 2 22 NOTES ...
Page 168: ...SAM47 INSTRUCTION SET KS57C2308 P2308 C2316 P2316 5 94 NOTES ...
Page 170: ......
Page 206: ...POWER DOWN KS57C2308 P2308 C2316 P2316 8 8 NOTES ...
Page 210: ...RESET KS57C2308 P2308 C2316 P2316 9 4 NOTES ...
Page 222: ...I O PORTS KS57C2308 P2308 C2316 P2316 10 12 NOTES ...
Page 272: ...LCD CONTROLLER DRIVER KS57C2308 P2308 C2316 P2316 12 24 NOTES ...
Page 280: ...SERIAL I O INTERFACE KS57C2308 P2308 C2316 P2316 13 8 NOTES ...
Page 294: ...MECHANICAL DATA KS57C2308 P2308 C2316 P2316 15 2 NOTES ...
Page 310: ...KS57P2308 P2316 OTP KS57C2308 P2308 C2316 P2316 16 16 NOTES ...
Page 318: ......
Page 320: ......
Page 322: ......
Page 325: ......
Page 327: ......