- 36 -
Damper Position Detection Error (E-A1)
Operate the Microwave Oven
for 1 minute and then
operate Oven mode.
YES
NO
NO
NO
YES
YES
YES
Does the Damper Swing
Motor work properly?
Replace the Damper Motor
Is the Micro Switch detected?
Is the Micro Switch terminal
properly connected?
S/W Error
The Micro Switch is defective.
Replace the Micro Switch.
Connect the Micro
Switch properly.
The voltage between the two terminals
while operating : 230V is normal.
The resistance of the Motor :
Approximately 15K is normal
Check if the terminal has
been inserted?
After Power > On,
does the symptom continue?
Replace the PCB.
Perform the operation again and check if it is working properly.
YES
NO
Perform the calibration
(Refer to page 18)
4-3-9 E-A1