4
EN
error Codes
Error Code
General Functions
TEMP SENSOR OPEN
In case the value of the temperature sensor is more than 250 °C during
operation / cancellation .
TEMP SENSOR SHORT
In case the value of the temperature sensor is less than 5 °C during
operation / cancellation .
OVER 210 °C DURING OPERATION OF MWO
In case the temperature rises over 210 °C during operation of MWO
(FIRE sensed)
DAMPER S/W
In case it fails to sense the DAMPER to open or close for 2 minutes .
CQ4250_HAC-00087A-01_EN.indd 47
2009-01-15 10:39:13
Summary of Contents for CQ4250
Page 1: ...Operating Instructions and Cooking Guide SPEED COOK OVEN CQ4250 Owner s Manual ...
Page 2: ......
Page 49: ...49 EN Note ...
Page 50: ...50 EN Note ...
Page 51: ...51 EN Note ...
Page 52: ...Code No DG68 00087A 02 ...