English - 11
English - 11
CONNECTING TO THE MAINS POWER SUPPLY
Before connecting, check that the nominal voltage of the
appliance, that is, the voltage stated on the rating plate,
corresponds to the available supply voltage. The rating plate is
located on the lower casing of the hob.
Shut off power to circuit before connecting wires to
circuit.
The heating element voltage is AC 230 V~. The appliance also
works perfectly on networks with AC 220 V~ or AC 240 V~.
The hob is to be connected to the mains using a device that
allows the appliance to be disconnected from the mains at
all poles with a contact opening width of at least 3 mm, eg.
automatic line protecting cut - out, earth leakage trips or fuse.
A type H05RN - F cable or one of a higher grade must be used as
the mains connecting cable.
Rated current of
appliance (A)
Nominal cross-sectional
area (mm
2
)
1N~
> 25 and ≤ 32
≥ 2.5
2N~
> 10 and ≤ 16
≥ 1.5
The connection must be carried out as shown in the diagram.
The connecting links should be fitted according to the appropriate
connection diagram.
The earth lead is connected to terminal. The earth lead must be
longer than leads carrying electric current.
The cable connections must be made in accordance
with regulations and the terminal screws tightened
securely.
The connecting cable is to be secured with the mains cable cleat
and the covering closed by pressing firmly (locking into place).
Before switching on for the first time, any protective foil or stickers
must be removed from the ceramic glass surface.
03
INS
TALLING THE HOB
WARNING
WARNING
CTR264KC01_XFA DG68-00446A-02_EN.indd 11
2016-09-02 �� 1:29:02