4. Troubleshooting
4-17
Error type
Error mode
Checking Method
Corrective actions
The nozzle does not
inject water.
None
4. Check the operation of the Circulation Motor Relay:
Check the operating voltage between the white wire
of the CN1 connector and the red wire of the CN14
connector on the Main PBA.
Normal: 120V (while operating)
➢
New PBA
4-1.Check the operation of the Circulation Motor Relay:
Check the operating voltage between the white wire of
the CN101 connector and the red wire of the CN201
connector on the Main PBA.
Normal: 120V (while operating)
➢
- Faulty: Replace the Main PBA assy.
- Normal: Replace the Circulation Motor.
5. Check the operation of the half load.
- See “PE Error”.
6. Check whether there is foreign material in the water
passages.
- Remove foreign material from the water passages.
No washing
None
1. Check whether the nozzle injects water normally.
- See “The nozzle does not inject water”.
2. Check the operation of the half load.
- See “PE Error”.
3. Check the operation of the Heater.
- See “HE Error”.
New PBA