Error 
Type

Error 
Mode

Cause

Reason

Tests Without Pulling D/W

Water
Supply
Error

4E

1. When the pulse of 100 or less is detected 
1 minute after the water supply starts
2. When flow meter pulse is 5 or less 5 
seconds after the water supply starts
3. No water detected 5 min after start

Water supply valve defect, Flow Meter 
defect, Particles within water supply 
valve, Water supply valve terminal not 
connected, Main PBA defect

Check valve resistance and 
voltage at brown wire at CN14 
to yellow wire at detergent 
dispenser 1.2 K ohms @ 120vac

Water
Supply
Error     
.   .          
Temp 
Sensor
Error

4E1    
.           
.           
.         
tE1

When 80

Ԩ

 or above is detected during 

water supply                                                          
.                                                                               
.                                                                               
When 0.2V or below, or 4.5V or above is 
maintained for over 3 seconds

Thermistor Defect, Water supply 
temperature of 80

Ԩ

 or above, Main PBA 

defect                                                                 
.                                                       
Thermistor terminal not connected
Thermistor Defect, Main PBA defect

Perform service test t3,                
for 3 minutes and compare 
display temp with actual water 
temp Celsius.  It should be 
within about 8 degrees C. 
Difference due to tank vs. sump 
temperature.

Drain 
Error

5E

When OFF status of Low Level S/W is not 
detected within3 minutes during the drain

Drain pump defect, Low Level Sensor 
defect, Particles clogging mater drain 
hose, Drain valve terminal not connected
Main PBA defect

Perform service test t6 Check 
motor resistance and voltage at 
white on CN1 to orange wires at 
CN14    42.2 ohms @ 120vac

Over-
flow
Error

oE

When overflow detection AD data is 4.0V or 
below for 3 seconds (When leakage sensor 
detects 4.0V or below for 1 seconds during 
water supply)

Foreign particles in water supply valve, 
Case Sensor part leakage, Flow Meter 
defect, Main PBA defect

Leak-
age
Error

LE

When leakage sensor detects 4.5V or below 
for 1 seconds

Base part hose connection defect
Sump and Tub assembly defect
Drain Pump assembly defect
Main PBA defect

Heater
Error

HE      
.           
.  .      
.    .      
.           
HE1

When the temperature change is 4

Ԩ

 or 

less within the first 10 minutes after the 
heating starts.                   .                                  
.                                                                               
.                                                                               
When the temperature of the Thermistor is 
80

Ԩ

 or above for more than 3 seconds

Heater defect
Heater Relay defect
Heater terminal not connected
Main Wire-Harness defect
Main PBA defect                                              
.                                                                
Heater Relay defect
Thermistor defect
Main PBA defect

Perform service test t3,                
will heat water approximately 1 
degree C per minute
If not working relay driver 
voltage is on main pcb red wire 
CN7 to white wire on door 
switch on right looking at back 
of panel. Will read 
approximately 50 ohms and 
12vdc off and 0.5vdc on.

Low 
Water
Level
Error

9E

When Low Level is detected to cause Error 
even after the water supply resumes after 
Low Level is detected for the 1st time

Low Level Sensor defect
Low Level Sensor not connected
Main PBA defect

service test t6                               
no water in tub = OFF, water in 
tub = ON possible float or micro 
switch issue

Button  
Error

bE2

When the button is pressed continuously 
for over 30 seconds

Sub PBA defect
Main PBA defect

Check for moisture in console

Half 
Load
Error

PE

When micro s/w is not detected for over 30 
seconds after the Distributor motor starts

Distributor motor defect                           
Micro sw terminal not connected 
Main PBA defect

Perform service test t8              
Violet wire CN 14 to Yellow 
wire at detergent dispenser 2.6 
K ohms @ 120vac

Samsung 'Dishwasher' Diagnostic Code Quick Guide

8

Summary of Contents for DMR57LFB/XAA

Page 1: ...Auto 0 45 5 30 17 30 17 30 17 30 11 30 46 30 7 30 7 30 12 30 46 30 20 58 181 No Sanitize Sanitize Normal 120 F 49 C 140 F 60 C 162 F 72 C Heavy 149 F 65 C 158 F 70 C 162 F 72 C Delicate 113 F 45 C 140 F 60 C 162 F 72 C Rinse Quick 113 F 45 C 140 F 60 C 162 F 72 C Smart Auto 113 149 F 45 65 C 140 158 F 60 70 C 162 F 72 C Pre wash 1 2 3 Rinse 1 2 Program Main wash Rinse 3 Dishwasher Cycle Chart Cond...

Page 2: ...Wiring Diagram after 5 1 2009 DMR57 77 78 2 ...

Page 3: ...Wiring Diagram before 5 1 2009 DMR57 3 ...

Page 4: ...Wiring Diagram before 5 1 2009 DMR77 78 4 ...

Page 5: ...CN801 Key Driver 11 12 5vdc CN502 Disp LED Driver DMR77 78 only CN501 Disp LED Driver CN11 Disp DriverDMR77 CN13 Display LED Driver CN1 PBA Power 1 120vac 3 120vac CN7 1 Power Relay Driver 2 Heater Relay Driver 3 Half Load Sensor DMR77 only 4 Trubidity Sensor 5 Trubidity Transmitter 7 6 5vdc 8 Rinse Aid Sensor 9 6 12vdc CN8 1 Low Water Sensor 3 Overflow Sensor 5 Water Counter 6 Leakage Sensor 8 Th...

Page 6: ...side of cavity during Installation verify proper loop Check for proper fill valve and flow meter in t1 test mode Water lost in distribution such as inside cups glasses bowls that flip over can cause a drop in water supplying the wash motor and can cause cavitation sound during any cycle Detergent Door Not Opening 1 Never overfill the dispenser compartment with powder or liquid only go below or up ...

Page 7: ... 31 996 104 26 065 113 21 385 122 17 599 Components Leaking and Poor Washability Check for split wash arms Dishwasher Parts Change 5 2009 Drying Concerns Condensing Dry System is used to conserve energy 1 Verify proper operation of Rinse Aid Dispensing 2 Verify Fan operation 3 Must use a Rinse Agent 4 Should use Sanitize Cycle 5 Should open door between 30 minutes and 3 hours after completion of t...

Page 8: ...conds during water supply Foreign particles in water supply valve Case Sensor part leakage FlowMeter defect Main PBA defect Leak age Error LE When leakage sensor detects 4 5V or below for 1 seconds Base part hose connection defect SumpandTubassembly defect Drain Pumpassembly defect Main PBA defect Heater Error HE HE1 When the temperature change is 4Ԩ or less within the first 10 minutes after the h...

Page 9: ...nd circulation pump 2 If a low water level is sensed water is supplied again and the operation continues 3 The current temperature is shown on the display 4 It operates up to 70ºC After temp increases 2 degrees C time is about 50 seconds for each degree C increase t4 Fan Motor Fan Motor not working Press the Delay Start key to start or stop the fan motor Listen for fan run ning t5 Drain Pump Low L...

Reviews: