Causes
Check Point
Thermistor, main PBA
ㆍ
1E error occurs when the temperature of the thermistor is 176 degrees F or above
for over 3 seconds.
#7. Error Code
7-1. 1E (High Temperature Heating Error)
Step 1
: Thermistor
!
Check the wiring connection to the thermistor.
"
Check for resistance of thermistor.
(
The Resistance (25
$
or 77
%
) : approximately 49.12kΩ
If the value is not normal, replace the thermistor.
Symptom
Step 2 :
Main PBA
ㆍ
1E error is displayed. (‘Normal’ + ‘Smart Auto’ LED On)
! "-#$%&!
Step 2 :
Main PBA
!
Check for the wire connection on main PBA
"
If there is no defect at the above steps, replace main PBA.