Causes
Check Point
Water tap, thermistor, main PBA
ㆍ
3E error occurs when a water temperature of 176
%
or above is detected during water
fill.
#7. Error Code
7-2. 3E (High Temperature Water Supply Error)
Step 2
: Thermistor
!
Check for the wire connection of thermistor.
Symptom
ㆍ
3E error is displayed. (‘Normal’ + ‘Delicate’ + ‘Smart Auto’ LED On)
Step 1
: Water Tap
!
Check for the hot water connections for the inlet valve.
(
Adjust the hot water supply so that the temperature of the supplied water is less than
176
%
(80
$
).
! '.#$%&!
!
Check for the wire connection of thermistor.
"
Check for resistance of thermistor.
(
The Resistance (25
$
or 77
%
) : approximately 49.12kΩ
If the value is not normal, replace the thermistor.
Step 3 :
Main PBA
!
Check for the wire connection on main PBA
"
If there is no defect at the above steps, replace main PBA.