Causes
Check Point
Drain hose, water level sensor, drain pump, main PBA
ㆍ
5E error occur, when OFF status of Low Level Switch is not detected within 3 minutes
during the drain.
#7. Error Code
7-4. 5E (Drain Error)
Step 2
: Water Level Sensor
Check the connections at the Water-level sensor.
Symptom
ㆍ
5E error is displayed. (‘Delicate’ LED On)
Step 1 :
Drain Hose
!
Check if drain hose is pinched or kinked.
"
Check if drain hose is clogged.
! '$#$%&!
!
Check the connections at the Water-level sensor.
"
Check the operation of the Water-level sensor.
(
If it is faulty, replace the assembly case sensor &
remove foreign material from the float
(
If it is normal, replace the Main PBA assembly.
Step 3
: Drain Pump
!
Check the connections at the Drain Pump connector.
"
Check the Drain Pump coil is resistance
(
The Resistance : approximately 25Ω (while operating)
If the value is not normal, replace the Drain pump.
Step 4
: Main PBA
!
Check the operation of the Drain Pump Relay.
→ Check the operating voltage between the yellow wire of the Main PBA CN101
connector and the orange wire of the CN202 connector.
(
The Voltage : AC 120V (while operating)
If the value is not normal, replace main PBA.