Causes
Check Point
Overflow sensor, water valve, case sensor
ㆍ
oE error occurs when the overflow detection AD data is 3.5V or below for 3 seconds
(When leakage sensor detects 3.5V or below for 1 seconds during water supply)
#7. Error Code
7-10. oE (Over Level Water Error)
Symptom
ㆍ
oE error is displayed. (‘Heavy’ + ‘Smart Auto’ LED On)
Step 1
: Overflow Sensor
!
Check the connections at the Overflow Sensor connector.
Step 2 :
Water Valve (1)
! '-#$%&!
Step 4
: Case Sensor
!
Check if there are any traces of water leakage on the top of
the Case Sensor
→ Clean the Hose-Sensor and the Case Sensor.
Step 3 :
Water Valve (2)
The voltage at the water valve when it is not operating is AC 120V,
!
Check for foreign materials in water valve and remove them.
If you can’t remove, replace the water valve.
"
If there are no foreign materials in water valve, replace main PBA.
!
Check the Resistance at the water valve.
(Remove the connector before checking)
(
The Resistance : 1.2kΩ
If the value is not normal, Replace the Water valve