4.
Troubleshooting
Code Symbol
Meaning
Occurring condition
Expected condition
Over-level water error
When overflow detection AD data is 4.0V or below for 3 seconds.
(When leakage sensor detects 4.0V or below for 1 seconds during water
supply).
Alien particles within water supply valve.
Case Sensor part leakage.
Possible defect : Flow Meter, Main PBA.
Leakage error
When leakage sensor detects 4.5V or below for 1 seconds.
Possible defect : Base part hose connection, Sump
and Tub assembly, Drain Pump assembly, Main PBA.
Button error
When the button is pressed continuously for over 30 seconds.
Possible defect : Sub PBA, Main PBA.
Door open warnning
When door is open in washing period.
Door is not close properly.
Possible defect : Door lock switch, Main PBA.
Copyright© 1995-2010 SAMSUNG. All rights reserved.
4-2