4. Troubleshooting
Error type
Error mode
Checking Method
Corrective actions
1) Check the connections for the power plug.
•
Reconnect the power plug.
2) Check the voltage of the power outlet.
•
Nomral: AC 120V
•
Connect to a 120V power source
3) Check the wires of the Main PBA power part.
•
Measure the voltage between the black wire and the white wire of
CN101.
•
Nomral: AC 120V
•
Faulty: Check and replace the wires of the power part.
•
Remove Retainer.
•
Check voltage.
Power error
None
4) Check the DC voltage of the Main PBA.
•
See “Main PBA DC voltage error”.
4-11
Copyright© 1995-2010 SAMSUNG. All rights reserved.