4.
Troubleshooting
Error type
Error mode
Checking Method
Corrective actions
1) Check the connections for the Door Sensing Switch
: Check the blue wire and the switch connected to the blue wire.
•
Normal (Power Key On): 9.5 to 12.5V (when the door is open)
•
Normal (Power Key Off): 5.5 to 7.0V (when the door is open)
•
Normal : <2V (when the door is closed)
•
Reconnect the Door Sensing Switch connectors
The Cycle does
not start.
None
2) Check the operation of the Door Sensing Switch.
(Remove the connector before measuring.)
: Check the blue wire and the switch connected to the blue wire.
•
Normal: OPEN (when the door is open)
•
Normal: SHORT (when the door is closed)
•
Faulty: Replace the Door Sensing Switch.
•
Normal: Replace the Main PBA assy.
1) Check whether the nozzle injects water normally.
•
See “The nozzle does not inject water”.
No Washing
None
2) Check the operation of the Heater.
•
See “Heater Error”.
Error type
Error mode
Checking Method
Corrective actions
1) Check the connections for the Door Sensing Switch
: Check the blue wire and the switch connected to the blue wire.
•
Normal: 4.5 to 5.5V (when the door is open)
•
Normal: < 1V (when the door is closed)
New PBA
1) Check the connections for the Door Sensing Switch
: Check the blue wire and the switch connected to the blue wire.
•
Normal: 9.5 to 13.0V (when the door is open)
•
Normal: < 1V (when the door is closed)
•
Reconnect the Door Sensing Switch connector.
The cycle does
not start.
None
Copyright© 1995-2010 SAMSUNG. All rights reserved.
4-14